Intraoperative electromyography monitoring in minimally invasive transforaminal lumbar interbody fusion

Author:

Bindal Rajesh K.12,Ghosh Subrata1

Affiliation:

1. 1Department of Neurosurgery, Baylor College of Medicine, Houston; and

2. 2Methodist Sugar Land Hospital, Sugar Land, Texas

Abstract

Object Minimally invasive transforaminal lumbar interbody fusion (TLIF) is an increasingly popular method for achieving lumbar decompression and fusion. The procedure is technically more demanding than open fusion, with correspondingly more theoretical risk of complication. The authors describe the use of intraoperative electromyography (EMG) as an adjunct to surgery to reduce the risk of complications. Methods Between August 2005 and April 2006, 25 consecutive patients underwent minimally invasive TLIF in which a total of 105 pedicle screws were placed. Intraoperative EMG was performed and included passive recordings during decompression and interbody graft placement, as well as active recording during the placement of the pedicle access needle and testing of the pedicle tap. A uniform protocol for active monitoring was used, with the pedicle access needle set at 7 mA. To assess hardware placement, all patients underwent postoperative radiography and 20 underwent postoperative computed tomography (CT) scanning. In no patient did the authors observe significant EMG activation during decompression. In five cases, intermittent nerve root firing was noted after the interbody graft was placed, but this did not correlate with any postoperative deficits. Using the active stimulation protocol, 76.2% of screw placements required one or more changes to the trajectory of the pedicle access needle. With successful placement of the pedicle access needle, in all 105 screws, the pedicle tap nerve root stimulation threshold was greater than 15 mA. Postoperative radiography was performed in all patients and CT scanning was performed in 20 patients (with 85 screws being placed). Postoperative imaging revealed only three cases of pedicle breach. In all cases, the breach was at the lateral wall of the pedicle and not thought to be clinically relevant. Conclusions A continuous stimulation pedicle access needle alerts the surgeon to incorrect medial trajectories and may lead to safer pedicle cannulation. As a result of electrophysiological feedback, the pedicle access needle trajectory was altered in 76.2% of the reported cases. The use of the authors’ protocol resulted in a 0% incidence of clinically relevant malpositioned hardware and a low overall neurological complication rate. Intraoperative nerve root monitoring is a useful adjunct to minimally invasive TLIF.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3