Impact of a contrast-to-noise ratio driven and material specific exposure control on image quality and radiation exposure in angiography

Author:

Werncke ThomasORCID,Kemling Marius,Tashenov Stanislav,Hinrichs Jan BORCID,Meine Timo C,Maschke Sabine K,Kyriakou Yiannis,Wacker Frank K,Meyer Bernhard C

Abstract

Abstract Conventional detector-dose driven exposure controls (DEC) do not consider the contrasting material of interest in angiography. Considering the latter when choosing the acquisition parameters should allow for optimization of x-ray quality and consecutively lead to a substantial reduction of radiation exposure. Therefore, the impact of a material-specific, contrast-to-noise ratio (CNR) driven exposure control (CEC) compared to DEC on radiation exposure was investigated. A 3D-printed phantom containing iron, tantalum, and platinum foils and cavities, filled with iodine, barium, and gas (carbon dioxide), was developed to measure the CNR. This phantom was placed within a stack of polymethylmethacrylate and aluminum plates simulating a patient equivalent thickness (PET) of 2.5–40 cm. Fluoroscopy and digital radiography (DR) were conducted applying either CEC or three, regular DEC protocols with parameter settings used in abdominal interventions. CEC protocols where chosen to achieve material-specific CNR values similar to those of DEC. Incident air kerma at the reference point(Ka,r), using either CEC or DEC, was assessed and possible Ka,r reduction for similar CNR was estimated. We show that CEC provided similar CNR as DEC at the same or lower Ka,r. When imaging barium, iron, and iodine Ka,r was substantially reduced below a PET of 20 cm and between 25 cm and 30 cm for fluoroscopy and Dr When imaging platinum and tantalum using fluoroscopy and DR and gas using DR, the Ka,r reduction was substantially higher. We estimate the Ka,r reduction for these materials between 15% and 84% for fluoroscopy and DR between 15% and 93% depending on the PET. The results of this study demonstrate a high potential for skin dose reduction in abdominal radiology when using a material-specific CEC compared to DEC. This effect is substantial in imaging materials with higher energy K-edges, which is beneficial, for example, in long-lasting embolization procedures with tantalum-based embolization material in young patients with arterio-venous malformations.

Funder

Siemens Healthineers

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3