Image Quality and Radiation Exposure in Abdominal Angiography

Author:

Werncke Thomas,Becker Lena S.,Maschke Sabine K.,Hinrichs Jan B.,Meine Timo C.H.,Dewald Cornelia L. A.,Brüsch Inga,Rumpel Regina,Wacker Frank K.,Meyer Bernhard C.

Abstract

Objectives This phantom and animal pilot study aimed to compare image quality and radiation exposure between detector-dose–driven exposure control (DEC) and contrast-to-noise ratio (CNR)–driven exposure control (CEC) as functions of source-to-image receptor distance (SID) and collimation. Materials and Methods First, an iron foil simulated a guide wire in a stack of polymethyl methacrylate and aluminum plates representing patient thicknesses of 15, 25, and 35 cm. Fluoroscopic images were acquired using 5 SIDs ranging from 100 to 130 cm and 2 collimations (full field of view, collimated field of view: 6 × 6 cm). The iron foil CNRs were calculated, and radiation doses in terms of air kerma rate were obtained and assessed using a multivariate regression. Second, 5 angiographic scenarios were created in 2 anesthetized pigs. Fluoroscopic images were acquired at 2 SIDs (110 and 130 cm) and both collimations. Two blinded experienced readers compared image quality to the reference image using full field of view at an SID of 110 cm. Air kerma rate was obtained and compared using t tests. Results Using DEC, both CNR and air kerma rate increased significantly at longer SID and collimation below the air kerma rate limit. When using CEC, CNR was significantly less dependent of SID, collimation, and patient thickness. Air kerma rate decreased at longer SID and tighter collimation. After reaching the air kerma rate limit, CEC behaved similarly to DEC. In the animal study using DEC, image quality and air kerma rate increased with longer SID and collimation (P < 0.005). Using CEC, image quality was not significantly different than using longer SID or tighter collimation. Air kerma rate was not significantly different at longer SID but lower using collimation (P = 0.012). Conclusions CEC maintains the image quality with varying SID and collimation stricter than DEC, does not increase the air kerma rate at longer SID and reduces it with tighter collimation. After reaching the air kerma rate limit, CEC and DEC perform similarly.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference26 articles.

1. Grids or air gaps for scatter reduction in digital radiography: a model calculation;Med Phys,1992

2. Scatter rejection by air gaps: an empirical model;Med Phys,1985

3. Impact of x-ray tube voltage, field size and object thickness on scattered radiation distribution in diagnostic radiology: a Monte Carlo investigation;2007 IEEE Nuclear Science Symposium Conference Record,2007

4. Collimation and image quality of C-arm computed tomography: potential of radiation dose reduction while maintaining equal image quality;Invest Radiol,2015

5. The operation logic of automatic dose control of fluoroscopy system in conjunction with spectral shaping filters;Med Phys,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3