A digital phoswich detector using time-over-threshold for depth of interaction in PET

Author:

Prout David LORCID,Gu Zheng,Shustef MaxORCID,Chatziioannou Arion F

Abstract

Abstract We present the performance of a digital phoswich positron emission tomography (PET) detector, composed by layers of pixilated scintillator arrays, read out by solid state light detectors and an application specific integrated circuit (ASIC). We investigated the use of integrated charge from the scintillation pulses along with time-over-threshold (ToT) to determine the layer of interaction (DOI) in the scintillator. Simulations were performed to assess the effectiveness of the ToT measurements for separating the scintillator events and identifying cross-layer-crystal-scatter (CLCS) events. These simulations indicate that ToT and charge integration from such a detector provide sufficient information to determine the layer of interaction. To demonstrate this in practice, we used a pair of prototype LYSO/BGO detectors. One detector consisted of a 19 × 19 array of 7 mm long LYSO crystals (1.36 mm pitch) coupled to a 16 × 16 array of 8 mm long BGO crystals (1.63 mm pitch). The other detector was similar except the LYSO crystal pitch was 1.63 mm. These detectors were coupled to an 8 × 8 multi-pixel photon counter mounted on a PETsys TOFPET2 ASIC. This high performance ASIC provided digital readout of the integrated charge and ToT from these detectors. We present a method to separate the events from the two scintillator layers using the ToT, and also investigate the performance of this detector. All the crystals within the proposed detector were clearly resolved, and the peak to valley ratio was 11.8 ± 4.0 and 10.1 ± 2.9 for the LYSO and BGO flood images. The measured energy resolution was 9.9% ± 1.3% and 28.5% ± 5.0% respectively for the LYSO and BGO crystals in the phoswich layers. The timing resolution between the LYSO–LYSO, LYSO–BGO and BGO–BGO coincidences was 468 ps, 1.33 ns and 2.14 ns respectively. Results show ToT can be used to identify the crystal layer where events occurred and also identify and reject the majority of CLCS events between layers.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Design and characterization of a hybrid PET detector with DOI capability;Medical Physics;2024-07-20

2. A continuous depth encoding PET detector using side readout of dual-layer GAGG crystals with SiPM array;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2024-02

3. Timing estimation of the exponentiated energy-weighted average for crosshair light sharing TOF-DOI PET detector;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2024-02

4. A multi-resolution TOF-DOI detector for human brain dedicated PET scanner;Physics in Medicine & Biology;2024-01-21

5. An LYSO and BGO checkerboard pattern detector with inter-crystal scatter identification capability;2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD);2023-11-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3