Abstract Objective. We propose a single-ended readout, multi-resolution detector design that can achieve high spatial, depth-of-interaction (DOI), and time-of-flight (TOF) resolutions, as well as high sensitivity for human brain-dedicated positron emission tomography (PET) scanners. Approach. The detector comprised two layers of LYSO crystal arrays and a lightguide in between. The top (gamma ray entrance) layer consisted of a 16 × 16 array of 1.53 × 1.53 × 6 mm3 LYSO crystals for providing high spatial resolution. The bottom layer consisted of an 8 × 8 array of 3.0 × 3.0 × 15 mm3 LYSO crystals that were one-to-one coupled to an 8 × 8 multipixel photon counter (MPPC) array for providing high TOF resolution. The 2 mm thick lightguide introduces inter-crystal light sharing that causes variations of the light distribution patterns for high DOI resolution. The detector was read out by a PETsys TOFPET2 application-specific integrated circuit. Main result. The top and bottom layers were distinguished by a convolutional neural network with 97% accuracy. All crystals in the top and bottom layers were resolved. The inter-crystal scatter (ICS) events in the bottom layer were identified, and the measured average DOI resolution of the bottom layer was 4.1 mm. The coincidence time resolution (CTR) for the top–top, top-bottom, and bottom–bottom coincidences was 476 ps, 405 ps, and 298 ps, respectively. When ICS events were excluded from the bottom layer, the CTR of the bottom–bottom coincidence was 277 ps. Significance. The top layer of the proposed two-layer detector achieved a high spatial resolution and the bottom layer achieved a high TOF resolution. Together with its high DOI resolution and detection efficiency, the proposed detector is well suited for next-generation high-performance brain-dedicated PET scanners.

Funder

GuangDong Basic and Applied Basic Research Foundation

National Key Research and Development Program of China

National Natural Science Foundation of China

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3