Blind source separation of inspiration and expiration in respiratory sEMG signals

Author:

Sauer JuliaORCID,Streppel MerleORCID,Carbon Niklas MORCID,Petersen EikeORCID,Rostalski PhilippORCID

Abstract

Abstract Objective. Surface electromyography (sEMG) is a noninvasive option for monitoring respiratory effort in ventilated patients. However, respiratory sEMG signals are affected by crosstalk and cardiac activity. This work addresses the blind source separation (BSS) of inspiratory and expiratory electrical activity in single- or two-channel recordings. The main contribution of the presented methodology is its applicability to the addressed muscles and the number of available channels. Approach. We propose a two-step procedure consisting of a single-channel cardiac artifact removal algorithm, followed by a single- or multi-channel BSS stage. First, cardiac components are removed in the wavelet domain. Subsequently, a nonnegative matrix factorization (NMF) algorithm is applied to the envelopes of the resulting wavelet bands. The NMF is initialized based on simultaneous standard pneumatic measurements of the ventilated patient. Main results. The proposed estimation scheme is applied to twelve clinical datasets and simulated sEMG signals of the respiratory system. The results on the clinical datasets are validated based on expert annotations using invasive pneumatic measurements. In the simulation, three measures evaluate the separation success: The distortion and the correlation to the known ground truth and the inspiratory-to-expiratory signal power ratio. We find an improvement across all SNRs, recruitment patterns, and channel configurations. Moreover, our results indicate that the initialization strategy replaces the manual matching of sources after the BSS. Significance. The proposed separation algorithm facilitates the interpretation of respiratory sEMG signals. In crosstalk affected measurements, the developed method may help clinicians distinguish between inspiratory effort and other muscle activities using only noninvasive measurements.

Funder

Drägerwerk AG & Co. KGaA, Lübeck, Germany

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3