In-line stereo-camera assisted robotic spot welding quality control system

Author:

Deniz Cengiz,Cakir Mustafa

Abstract

Purpose The purpose of this study is to design a robotic inline measurement system for spot welding quality control to achieve process requirement without any operator during the manufacturing flow. Design/methodology/approach A robot manipulator carries a stereo-camera and an ultrasonic control probe. The center position of the spot welding point is determined by evaluating the results of the edge, gradient and symmetry approaches from the methods proposed up to now in the literature to increase reliability. The center position of the spot welding point, determined in the camera reference plane, is transferred to the robot base plane coordinates with the hand–eye calibration proposed in this manuscript. Weld quality is checked by the ultrasonic test probe located at the spot welding point. Findings While operators can only control welding quality, the developed station can also evaluate the quality based on geometric accuracy by processing the deviation of the position of the spot welding points. The proposed calibration method and the results of other methods in the literature are presented in this study by comparing it with synthetic data in simulations and in practical application. Research limitations/implications The quality control is performed not only for the spot welding made with robots but also for the manual welds as well. Because of vision configuration, and reliability issues, maximum allowable offset by the correct spot position is limited to 20 mm to position the manipulator for testing. The installation and pretest works of the developed robotic welding quality control station are completed in the Body Shop Area of Ford Otosan factory in Kocaeli/Turkey. The results of the robotic control process are monitored by the quality assurance team. Integration of automation with the production line will be completed and an inline measurement will be done. Originality value In this paper, a new hand–eye calibration method based on simple and closed-form analytical solutions has been presented. The objective function is defined as reducing the deviation in the point projection, rather than reducing the error in the calibration equation. To increase reliability, combining the results of existing centering algorithms for the detection of the strongly deformed spot welding spot center, although it is normally in a circular form, has been suggested.

Publisher

Emerald

Subject

Industrial and Manufacturing Engineering,Computer Science Applications,Control and Systems Engineering

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3