Author:
Deniz Cengiz,Cakir Mustafa
Abstract
Purpose
The purpose of this study is to design a robotic inline measurement system for spot welding quality control to achieve process requirement without any operator during the manufacturing flow.
Design/methodology/approach
A robot manipulator carries a stereo-camera and an ultrasonic control probe. The center position of the spot welding point is determined by evaluating the results of the edge, gradient and symmetry approaches from the methods proposed up to now in the literature to increase reliability. The center position of the spot welding point, determined in the camera reference plane, is transferred to the robot base plane coordinates with the hand–eye calibration proposed in this manuscript. Weld quality is checked by the ultrasonic test probe located at the spot welding point.
Findings
While operators can only control welding quality, the developed station can also evaluate the quality based on geometric accuracy by processing the deviation of the position of the spot welding points. The proposed calibration method and the results of other methods in the literature are presented in this study by comparing it with synthetic data in simulations and in practical application.
Research limitations/implications
The quality control is performed not only for the spot welding made with robots but also for the manual welds as well. Because of vision configuration, and reliability issues, maximum allowable offset by the correct spot position is limited to 20 mm to position the manipulator for testing. The installation and pretest works of the developed robotic welding quality control station are completed in the Body Shop Area of Ford Otosan factory in Kocaeli/Turkey. The results of the robotic control process are monitored by the quality assurance team. Integration of automation with the production line will be completed and an inline measurement will be done.
Originality value
In this paper, a new hand–eye calibration method based on simple and closed-form analytical solutions has been presented. The objective function is defined as reducing the deviation in the point projection, rather than reducing the error in the calibration equation. To increase reliability, combining the results of existing centering algorithms for the detection of the strongly deformed spot welding spot center, although it is normally in a circular form, has been suggested.
Subject
Industrial and Manufacturing Engineering,Computer Science Applications,Control and Systems Engineering
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献