Author:
Copelovici Noémie,Tran Maï-Linh,Lefebvre François,Laheurte Pascal,Wagner Delphine
Abstract
ABSTRACT
Objectives
To assess the super-elasticity of CuNiTi wires (Ormco, Glendora, Calif) according to their Austenite finish temperature (Af) and to the imposed displacement. The secondary objective was to compare the wire dimensions with the stated measurements and to study interbatch variability.
Materials and Methods
10 types of CuNiTi wires (Ormco, Glendora, Calif) (n = 350) were investigated at 36 ± 1°C, with conventional brackets (Victory Series, 3M Unitek, Monrovia, Calif). Tensile test with coronoapical displacement ranging from 1 to 5 mm of the canine bracket was imposed. The wire dimensions were initially measured from two batches (n = 10).
Results
Dimensional heterogeneity varied by ± 2.00% compared to the manufacturer's data, and even up to 5.54% for 0.014-inch CuNiTi (P = .00069). However, all unloading forces were reproducible. In decreasing order, the forces delivered by a CuNiTi 27 were greater than those with CuNiTi 35 and 40. The super-elasticity was expressed only for displacements of 1 to 2 mm, at best up to 3 mm for 0.014-inch CuNiTi 27.
Conclusions
The value of Af as well as the amount of imposed displacement seem to influence the expression of the super-elasticity of CuNiTi wires and the amount of corrected malocclusion. Among the tested wires, under these experimental conditions, 0.014-inch wire could be suitable as a first archwire. CuNiTi 35, therefore, seems to offer the best compromise among the force level, the expression of super-elasticity and the amount of malocclusion correction.
Publisher
The Angle Orthodontist (EH Angle Education & Research Foundation)
Reference34 articles.
1. Keim
RG,
Vogels
DS,
Iii
Vogels
PB.
2020 JCO Study of Orthodontic Diagnosis and Treatment Procedures Part 1: Results and Trends.
J Clin Orthod.
2020;
54(10):
581–
610.
2. Wang
Y,
Liu
C,
Jian
F,
et al.
Initial arch wires used in orthodontic treatment with fixed appliances.
Cochrane Database Syst Rev.2018;
7(7):
CD007859.http://doi.org/10.1002/14651858.CD007859.pub4.
3. Miura
F,
Mogi
M,
Ohura
Y,
Hamanaka
H.
The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics.
Am J Orthod Dentofacial Orthop.
1986;
90(1):
1–
10.
http://doi.org/10.1016/0889-5406(86)90021-1.
4. Sachdeva
RCL,
Miyazaki
S,
Farzin-Nia
F.
Orthodontic archwire and method of moving teeth.
US Patent US5044947A.September 3, 1991.
5. Gil
FJ,
Solano
E,
Peña
J,
Engel
E,
Mendoza
A,
Planell
JA.
Microstructural, mechanical and citotoxicity evaluation of different NiTi and NiTiCu shape memory alloys.
J Mater Sci Mater Med.
2004;
15(11):
1181–
1185.
http://doi.org/10.1007/s10856-004-5953-8.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献