Non-reproducible cardiac troponin results occurring with a particular reagent lot
Author:
Affiliation:
1. Department of Laboratory Medicine , Clinique St-Luc Bouge , Namur , Belgium
2. Department of Cardiology , Clinique St-Luc Bouge , Namur , Belgium
Publisher
Walter de Gruyter GmbH
Subject
Biochemistry, medical,Clinical Biochemistry,General Medicine
Link
https://www.degruyter.com/document/doi/10.1515/cclm-2020-0562/pdf
Reference12 articles.
1. Ungerer, JP, Pretorius, CJ, Dimeski, G, O’Rourke, PK, Tyack, SA. Falsely elevated troponin I results due to outliers indicate a lack of analytical robustness. Ann Clin Biochem 2010;47:242–7. https://doi.org/10.1258/acb.2010.010012.
2. Ryan, JB, Southby, SJ, Stuart, LA, Mackay, R, Florkowski, CM, George, PM. Comparison of cardiac TnI outliers using a contemporary and a high-sensitivity assay on the Abbott Architect platform. Ann Clin Biochem 2014;51:507–11. https://doi.org/10.1177/0004563214534637.
3. Sawyer, N, Blennerhassett, J, Lambert, R, Sheehan, P, Vasikaran, SD. Outliers affecting cardiac troponin I measurement: comparison of a new high sensitivity assay with a contemporary assay on the Abbott ARCHITECT analyser. Ann Clin Biochem 2014;51:476–84. https://doi.org/10.1177/0004563213499737.
4. Warner, JV, Marshall, GA. High incidence of macrotroponin I with a high-sensitivity troponin I assay. Clin Chem Lab Med 2016;54:1821–9. https://doi.org/10.1515/cclm-2015-1276.
5. Lippi, G, Aloe, R, Meschi, T, Borghi, L, Cervellin, G. Interference from heterophilic antibodies in troponin testing. Case report and systematic review of the literature. Clin Chim Acta 2013;426:79–84. https://doi.org/10.1016/j.cca.2013.09.004.
Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Investigating outlier rates of cardiac troponin I and troponin T assays: A systematic review;Heliyon;2024-01
2. Lot-to-lot variation and verification;Clinical Chemistry and Laboratory Medicine (CCLM);2022-11-24
3. Two-site evaluation of the Roche Elecsys Vitamin D total III assay;Clinical Chemistry and Laboratory Medicine (CCLM);2022-07-15
4. Interferences in immunoassays: review and practical algorithm;Clinical Chemistry and Laboratory Medicine (CCLM);2022-03-18
5. Measurement in different sample types may aid in detecting interferences and macrocomplexes affecting cardiac troponin measurements;Clinical Chemistry and Laboratory Medicine (CCLM);2022-01-06
1.学者识别学者识别