A national surveillance program for evaluating new reagent lots in medical laboratories

Author:

Solsvik Anne Elisabeth1,Kristoffersen Ann Helen12,Sandberg Sverre123,Gidske Gro13,Stavelin Anne Vegard1,Eikeland Joakim4,Amundsen Erik14

Affiliation:

1. Norwegian Organization for Quality Improvement of Laboratory Examinations (Noklus), Haraldsplass Deaconess Hospital , Bergen , Norway

2. Department of Medical Biochemistry and Pharmacology , Haukeland University Hospital , Bergen , Norway

3. Department of Global Public Health and Primary Care , Faculty of Medicine, University of Bergen , Bergen , Norway

4. Department of Medical Biochemistry , Oslo University Hospital , Oslo , Norway

Abstract

Abstract Objectives Differences between laboratory results attributable to the use of different reagent lots can potentially affect the diagnosis and monitoring of patients. To minimize patient risks, all laboratories should verify that new reagent lots meet agreed analytical performance specifications (APS). We propose a simplified, pragmatic approach for laboratories that involves compilating results into a national surveillance program, and present the first results obtained when applying this approach to troponins, glycated hemoglobin (HbA1c), prostate-specific antigen (PSA) and D-dimer. Methods In the surveillance program we have (i) determined APS for selected analytes, (ii) implemented a simplified procedure for lot evaluation with patient samples used in laboratories across Norway and (iii) performed central processing of the results from the participating laboratories. Results Over a one-year period, 27 Norwegian laboratories returned results from 28 lot changes for troponin I, 11 for troponin T, and 29 for HbA1c, PSA and D-dimer. The mean difference between two reagent lots was 4.5% for troponin I (for a concentration interval of 20–32 ng/L), 5.1% for troponin T (10.7–17.5 ng/L), 2.2% for HbA1c (40–50 mmol/mol), 3.7% for PSA (3–5 μg/L) and 5.5% for D-dimer (0.4–1.0 mg/L FEU). Conclusions A novel procedure for reagent lot evaluation is proposed in which information about multiple lot changes from different medical laboratories can be accumulated nationally. Sharing this information allows simplification of lot evaluations in individual laboratories and provides real-world data about lot-to-lot variations.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3