Between-Lot Variation in External Quality Assessment of Glucose: Clinical Importance and Effect on Participant Performance Evaluation

Author:

Kristensen Gunn BB1,Christensen Nina Gade1,Thue Geir1,Sandberg Sverre1

Affiliation:

1. NOKLUS, Norwegian Quality Improvement of Primary Care Laboratories, Section for General Practice, Department of Public Health and Primary Health Care, University of Bergen, Bergen, Norway

Abstract

Abstract Background: External quality assessment schemes (EQAS) are conducted to evaluate user performance (participant assessment) and to assess different methods and instruments (method assessment). The quality of control materials is crucial to achieving these goals. Inconsistencies in between-lot variations detected by use of different control and sample materials may affect EQAS outcomes. Methods: For the Accu-Chek Sensor, Precision Xtra, Ascensia Elite, and HemoCue 201 glucometers, 3 different lots of glucose strips were used with each instrument. Method assessment results from analysis of capillary blood and 3 control materials were used to calculate between-lot differences. A simulation study was performed to evaluate the effect of between-lot variation on participant assessment results. Results: With the Precision Xtra, the results obtained with EQA control material mirrored those obtained with capillary blood, but for the other instruments, we found between-lot differences of as much as 1.3 mmol/L, which were substantially greater than those found with capillary blood and of clinical importance at decision limits. The simulation study showed an effect on participant assessment results related to the target values, with the percentage of poor results decreasing (38%, 10%, and 4%) with the use of common, method-specific, and lot-specific target values, respectively. Conclusions: Between-lot variation may influence participant EQA results for participant and method assessments. The clinical relevance of between-lot variation discovered in EQAS using noncommutable control materials should be examined by use of native blood samples.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Reference25 articles.

1. Libeer JC, Baadenhuijsen H, Fraser CG, Petersen PH, Ricos C, Stockl D, et al. Characterization and classification of external quality assessment schemes (EQA) according to objectives such as evaluation of method and participant bias and standard deviation. External Quality Assessment (EQA) Working Group A on Analytical Goals in Laboratory Medicine. Eur J Clin Chem Clin Biochem1996;34:665-678.

2. Sciacovelli L, Zardo L, Secchiero S, Plebani M. Quality specifications in EQA schemes: from theory to practice. Clin Chim Acta2004;346:87-97.

3. ILAC Technical Accreditation Issues Committee. ILAC-G13:2000—guidelines for the requirements for the competence of providers for proficiency testing schemes. http://www.ilac.org (accessed January 2005)..

4. Thienpont LM, Leenheer AP, Stockl D, Reinauer H. Candidate reference methods for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. II. Method transfer. Clin Chem1993;39:1001-1006.

5. Burrin J, Alberti K. What is blood glucose: can it be measured?. Diabetic Med1990;7:199-206.

Cited by 67 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3