Comprehensive study of the radiation shielding feature of polyester polymers impregnated with iron filings

Author:

Al-Saleh Wafa M.12,Dahi Mai R. H.3,Sayyed M. I.4,Almutairi Haifa M.5,Saleh I. H.6,Elsafi Mohamed3

Affiliation:

1. College of Science and Health Professions, King Saud Bin Abdulaziz University for Health Sciences, Hofuf, Al-Ahsa , P.O. Box 6664 Al-Ahsa, 31982 , Saudi Arabia

2. King Abdullah International Medical Research Center, Hofuf , Al-Ahsa , Saudi Arabia

3. Physics Department, Faculty of Science, Alexandria University , 21511 Alexandria , Egypt

4. Department of Physics, Faculty of Science, Isra University , Amman , Jordan

5. Medical Physics Department, Umm Al-Qura University , Prince Sultan Bin Abdul-Aziz Road , Mecca , Saudi Arabia

6. Department of Environmental Studies, Institute of Graduate Studies and Research, Alexandria University , Alexandria , Egypt

Abstract

Abstract Radiation and nuclear technologies have side effects in addition to their important applications, so appropriate shields must be used to protect users and the public from high doses as a result of exposure to this radiation. In this work, the attenuation coefficients for polyester composites doped with waste iron filings (IFs) were studied. Six samples of different IF concentrations were manufactured, namely, Poly, Poly-IF20, Poly-IF30, Poly-IF40, Poly-IF50, and Poly-IF60 (where Poly-IF60 represents 40% polyester and 60% IF). We measured the attenuation factors using high purity germanium (HPGe)-detector along with three radioactive sources 241Am (emitting energy of 0.06 MeV), 137Cs (emitting energy of 0.662 MeV), and Co-60 (emitting energy of 1.173 and 1.333 MeV). We compared the linear attenuation coefficient (LAC) obtained by theoretical (i.e., XCOM software) and experimental (i.e., HPGe-detector) approaches for the prepared polyester composites at various photon energies (0.060, 0.662, 1.173, and 1.333 MeV). The greatest difference between the LAC values of the samples occurs at 0.060 MeV, where the Poly-IF60 sample has a much greater LAC than the other shields, followed by the Poly-IF50 sample, Poly-IF40 sample, and so on until the pure polyester shield. Specifically, their values are equal to 0.245, 0.622, 0.873, 1.187, 1.591, and 2.129 cm−1 for Poly, Poly-IF20, Poly-IF30, Poly-IF40, Poly-IF50, and Poly-IF60, respectively. We calculated the transmission factor (TF) and the radiation shielding efficiency (RSE), and found that the TF for Poly-IF30 is equal to 28.82%, 77.94%, 82.75%, and 83.75% at 0.060, 0.662, 1.173, and 1.333, respectively, while its RSE is equal to 82.57%, 24.00%, 18.80%, and 17.72%, respectively. The fast neutron removal cross-section (FNRC) of the polyester samples was calculated and the values increase when more Ifs are added to the samples. More specifically, the FNRC values are equal to 0.095, 0.100, 0.103, 0.107, 0.110, and 0.113 cm−1 for Poly, Poly-IF20, Poly-IF30, Poly-IF40, Poly-IF50, and Poly-IF60, respectively.

Publisher

Walter de Gruyter GmbH

Subject

Polymers and Plastics,Physical and Theoretical Chemistry,General Chemical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3