Methods to identify saline-contaminated electrolyte profiles

Author:

Patel Devin K.,Naik Rishi D.,Boyer Richard B.,Wikswo John,Vasilevskis Eduard E.

Abstract

AbstractWith providers becoming more selective in ordering daily chemistry profiles, it is critical that profiles ordered are accurate. Contaminated electrolyte profiles are an overlooked and potentially dangerous source of inaccurate clinical data. This study aimed to develop a method to accurately identify electrolyte profiles contaminated with normal saline to prevent reporting of erroneous measurements.We conducted a retrospective cohort study of 76,497 electrolyte profiles from 5032 patients in a deidentified clinical database of all patients in the electronic medical record at Vanderbilt University Medical Center. Five methods to identify errors in quantification based on either deviations from observed concentration distributions or expected numerical changes from saline contamination were developed and tested. Potentially contaminated measurements were validated based on changes in electrolyte concentrations observed in the subsequent sample.Identification of erroneous electrolyte profiles based on absolute and percent deviations from normal variation rarely resulted in >50% of identified samples validated as contaminated. A targeted methodology based on expected changes in calcium and chloride concentrations due to saline contamination validated approximately 80% of identified samples when higher thresholds for changes in electrolyte concentration were used and 50% of identified samples when lower thresholds were used.Targeted methodology based on changes in chloride and calcium successfully identified electrolyte profiles suspicious for contamination. Implementation of this methodology could prevent misinterpretation of a patient’s clinical course, inappropriate interventions, and unwarranted changes in treatment strategy.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference64 articles.

1. False - positive immunoassay results : a multicenter survey of erroneous immunoassay results from assays of analytes in donors from laboratories in seven countries;Marks;Clin Chem,2002

2. emergencies;Tohme;Endocrinol Metab Clin Am,1993

3. Striving for perfection;Leape;Clin Chem,2002

4. Reducing unnecessary inpatient laboratory testing in a teaching hospital;May TA;Am J Clin Pathol,2006

5. Accuracy of drawing coagulation samples from heparinized arterial lines;Templin;Am J Crit Care,1993

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3