Abstract
AbstractVentilating of multi pane-glazed windows using wasted air of buildings is an effective technique to minimize heat loss through windows and save heating energy in cold regions. In low-scaled occupancy buildings with high WWR ratio, buildings supply a low flow rate of wasted air to windows ventilation systems, resulting in a declination in its thermal performance. Therefore, this study introduces methods of managing the utilisation of wasted air in windows ventilation to optimise the energy saving. Two methods have been implemented experimentally on a small-scaled room. The first method is a time-based division of air pump operation, an air pump ventilates multiple windows, one window at a time repetitively. The second method shares the available wasted air to multiple windows. The experimental results and mathematical heat transfer model have been employed to evaluate thermal performance of the system in different methods. The first method showed a best energy saving with a duty cycle of 50% for the air pump, and on/off operation every 10 s. An energy saving of 42.6% has been realized compared to the traditional double-glazed windows, and the heat transfer coefficient was declined from 3.82 to 2.8 W/m2 K. The second method showed an optimum thermal performance when the available flow rate of wasted air was shared with three double-glazed windows. An energy saving of 83.1% was achieved compared to the traditional double-glazed windows, and the heat transfer coefficient dropped from 3.82 to 2.36 W/m2 K.
Publisher
Springer Science and Business Media LLC
Subject
General Energy,Environmental Engineering
Reference37 articles.
1. Li, H.W.S.G.: Summarization of present building energy consumption and corresponding strategies in China. Environ. Sci. Manag. 33(2), 6–9 (2008)
2. International Energy Agency, Statistics and Data. (2018). https://www.iea.org/
3. Zemitis, J., Borodinecs, A.: Energy saving potential of ventilation systems with exhaust air heat recovery. IOP Conf. Ser. Mater. Sci. Eng. (2019). https://doi.org/10.1088/1757-899X/660/1/012019
4. Lu, N., Taylor, T., Jiang, W., Correia, J., Leung, L.R., Wong, P.C.: The temperature sensitivity of the residential load and commercial building load. In: 2009 IEEE Power and Energy Society General Meeting, PES ’09 (2009). https://doi.org/10.1109/PES.2009.5275654
5. Jiang, Z. and Rahimi-Eichi, H.: Design, modeling and simulation of a green building energy system. In: 2009 IEEE Power and Energy Society General Meeting, PES ’09, pp. 1–7 (2009). https://doi.org/10.1109/PES.2009.5275755.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献