Affiliation:
1. Nanjing Institute of Agricultural Mechanization, Ministry of Agriculture and Rural Affairs, Nanjing, 210014/China
Abstract
In order to study the effect of population disturbance on the filling performance of the seed metering device, this paper uses the pneumatic precision seed metering device as the model, and uses EDEM software to simulate the population movement of three different seed metering devices. The bench test was carried out at different pressures at 12 km/h and at different speeds at 3.5 kPa. The results show that the designed seed disk with grooves has the most intense disturbance and the highest qualified rate. In order to verify the performance of the disk, full factor tests are carried out on the air pressure and speed, The test results show that when the operating speed is 10~12 km/h and the positive pressure is 3~3.5 kPa, the leakage rate is no higher than 5.42%, the replay rate is no higher than 0.42%, and the qualified rate is no lower than 94.58%. When the operating speed is 14 ~ 16 km/h and the positive pressure is 3.5~4 kPa, the leakage rate is not higher than 6.7%, the replay rate is not higher than 1.04%, and the pass rate is not lower than 93.12%. All the indicators are better than the national standard.