The Effect of Overshooting the Target Strain on Estimating Viscoelastic Properties From Stress Relaxation Experiments
Author:
Gimbel Jonathan A.1, Sarver Joseph J.1, Soslowsky Louis J.1
Affiliation:
1. McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA 19104-6081
Abstract
Background: Tendon’s mechanical behaviors have frequently been quantified using the quasi-linear viscoelastic (QLV) model. The QLV parameters are typically estimated by fitting the model to a single-step stress relaxation experiment. Unfortunately, overshoot of the target strain occurs to some degree in most experiments. This has never been formally investigated even though failing to measure, minimize, or compensate for overshoot may cause large errors in the estimation of parameters. Therefore, the objective of this study was to investigate the effect of overshoot on the estimation of QLV parameters. Method of approach: A simulated experiment was first performed to quantify the effect of different amounts of overshoot on the estimated QLV parameters. Experimental data from tendon was then used to determine if the errors associated with overshoot could be reduced when a direct fit is used (i.e., the actual strain history was used in the curve fit). Results: We found that both the elastic and viscous QLV parameters were incorrectly estimated if overshoot was not properly accounted for in the fit. Furthermore, the errors associated with overshoot were partially reduced when overshoot was accounted for using a direct fit. Conclusions: A slow ramp rate is recommended to limit the amount of overshoot and a direct fit is recommended to limit the errors associated with overshoot, although other approaches such as adjusting the control system to limit overshoot could also be utilized.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference10 articles.
1. Fung, Y. C., 1972, “Stress–Strain-History Relations of Soft Tissues in Simple Elongation,” in Biomechanics: Its Foundations and Objectives, edited by Y. C. Fung, N. Perrone, and M. Anliker, Prentice-Hall, San Diego, pp. 181–208. 2. Woo, S. L., Johnson, G. A., and Smith, B. A., 1993, “Mathematical Modeling of Ligaments and Tendons,” J. Biomech. Eng., 115, pp. 468–473. 3. Kwan, M. K., Lin, T. H., and Woo, S. L., 1993, “On the Viscoelastic Properties of the Anteromedial Bundle of the Anterior Cruciate Ligament,” J. Biomech., 26, pp. 447–452. 4. Nigul, I., and Nigul, U., 1987, “On Algorithms of Evaluation of Fung’s Relaxation Function Parameters,” J. Biomech., 20, pp. 343–352. 5. Thomopoulos, S., Williams, G. R., Gimbel, J. A., Favata, M., and Soslowsky, L. J., 2003, “Variation of Biomechanical, Structural, and Compositional Properties Along the Tendon to Bone Insertion Site,” J. Orthop. Res., 21, pp. 413–419.
Cited by
37 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|