Investigating Viscoelastic Properties of Myofibrils Isolated From hiPSC-CMs Using Atomic Force Microscopy and Quasi-Linear Viscoelastic Model

Author:

Jannati Shayan1,Maaref Yasaman2,Tibbits Glen F.3,Chiao Mu4

Affiliation:

1. University of British Columbia BC Children’s Hospital Research Institute, Microelectromechanical Systems Laboratory, Department of Mechanical Engineering, , Vancouver, BC V6T 1Z4 , Canada

2. Simon Fraser University BC Children’s Hospital Research Institute, Department of Biomedical Physiology and Kinesiology, , Burnaby, BC V6A 1S6 , Canada

3. Simon Fraser University BC Children’s Hospital Research Institute, Departments of Biomedical Physiology and Kinesiology and Molecular Biology and Biochemistry, , Burnaby, BC V6A 1S6 , Canada

4. University of British Columbia Microelectromechanical Systems Laboratory, Department of Mechanical Engineering, , Vancouver, BC V6T 1Z4 , Canada

Abstract

Abstract Knowing the mechanical properties of cardiac myofibrils isolated from human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) can provide valuable insight into the structure and function of the heart muscle. Previous studies focused mostly on studying myofibrillar stiffness using simplified elastic models. In this study, the mechanical properties of myofibrils isolated from hiPSC-CMs were measured using atomic force microscopy (AFM). The quasi-linear viscoelastic (QLV) model was used to interpret the elastic and viscous properties of myofibrils. Since there have been no previous studies on the viscoelastic properties of myofibrils extracted from hiPSC-CMs, myofibrils extracted from porcine left-ventricular (LV) tissue were used to compare and verify experimental processes and QLV model parameters. The elastic modulus of myofibrils extracted from porcine LV tissue was determined to be 8.82 ± 6.09 kPa which is consistent with previous studies which reported that porcine LV tissue is less stiff on average than mouse and rat cardiac myofibrils. The elastic modulus of myofibrils extracted from hiPSC-CMs was found to be 9.78 ± 5.80 kPa, which is consistent with the range of 5–20 kPa reported for myofibrils extracted from the adult human heart. We found that myofibrils isolated from hiPSC-CMs relax slower than myofibrils extracted from porcine LV tissue, particularly in the first 0.25 s after the peak stress in the stress relaxation test. These findings provide important insights into the mechanical behavior of hiPSC-CMs and have implications for the development of treatments for heart diseases.

Publisher

ASME International

Subject

Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3