A Multiaxial Computer-Controlled Organ Culture and Biomechanical Device for Mouse Carotid Arteries
Author:
Gleason R. L.1, Gray S. P.1, Wilson E.2, Humphrey J. D.3
Affiliation:
1. Department of Biomedical Engineering, Texas A&M University, College Station, TX 2. Department of Medical Physiology and Cardiovascular Research Institute, Texas A&M University System Health Science Center, College Station, TX 3. Department of Biomedical Engineering and M.E. DeBakey Institute, Texas A&M University, College Station, TX
Abstract
Much of our understanding of vascular mechanotransduction has come from studies using either cell culture or in vivo animal models, but the recent success of organ culture systems offers an exciting alternative. In studying cell-mediated vascular adaptations to altered loading, organ culture allows one to impose well-controlled mechanical loads and to perform multiaxial mechanical tests on the same vessel throughout the culture period, and thereby to observe cell-mediated vascular adaptations independent of neural and hormonal effects. Here, we present a computer-controlled perfused organ culture and biomechanical testing device designed for small caliber (50–5000 micron) blood vessels. This device can control precisely the pulsatile pressure, luminal flow, and axial load (or stretch) and perform intermittent biaxial (pressure–diameter and axial load–length) and functional tests to quantify adaptations in mechanical behavior and cellular function, respectively. Device capabilities are demonstrated by culturing mouse carotid arteries for 4 days.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference34 articles.
1. Bardy, N., Karillon, G. J., Merval, R., Samuel, J.-L., and Tedgui, A., 1995, “Differential Effects of Pressure and Flow on DNA and Protein Synthesis and on Fibronectin Expression by Arteries in a Novel Organ Culture System,” Circ. Res., 77, pp. 684–694. 2. Labadie, R. F., Antaki, J. F., Williams, J. L., Katyal, S., Ligush, J., Watkins, S. C., Pham, S. M., and Borovetz, H. S., 1996, “Pulsatile Perfusion System for Ex Vivo Investigation of Biochemical Pathways in Intact Vascular Tissue,” Am. J. Physiol., 270(Heart Circ. Physiol. 39 pp. ), H760–H768H760–H768. 3. Chestler, N. C., Conklin, B. S., Han, H.-C., and Ku, D. K., 1998, “Simplified Ex Vivo Artery Culture Techniques for Porcine Arteries,” Annu. Rep. Prog. Chem., Sect. C: Phys. Chem., 4, pp. 123–127. 4. Matsumoto, T., Okumura, E., Miura, Y., and Sato, M., 1999, “Mechanical and Dimensional Adaptation of Rabbit Carotid Artery In Vitro,” Med. Biol. Eng. Comput., 37, pp. 252–256. 5. Bakker, E. N. T. P., van der Meulen, E. T., Spaan, J. A. E., and VanBavel, E., 2000, “Organoid Culture of Cannulated Rat Resistance Arteries: Effect of Serum Factors on Vasoactivity and Remodeling,” Am. J. Physiol., 278, pp. H1233–H1240H1233–H1240.
Cited by
143 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|