Strain Uniformity in Biaxial Specimens is Highly Sensitive to Attachment Details

Author:

Eilaghi Armin1,Flanagan John G.2,Brodland G. Wayne3,Ethier C. Ross4

Affiliation:

1. Department of Mechanical and Industrial Engineering, and Institute for Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, M5S 1A1

2. Department of Ophthalmology and Vision Sciences, University of Toronto; School of Optometry School, University of Waterloo, Waterloo, Ontario, N2L 3G1

3. Department of Civil and Environmental Engineering, and Department of Biology, University of Waterloo

4. Department of Mechanical and Industrial Engineering, Institute for Biomaterials and Biomedical Engineering, and Department of Ophthalmology and Vision Sciences, University of Toronto; Department of Bioengineering, Imperial College, London SW7 2AZ, UK

Abstract

Biaxial testing has been used widely to characterize the mechanical properties of soft tissues and other flexible materials, but fundamental issues related to specimen design and attachment have remained. Finite element models and experiments were used to investigate how specimen geometry and attachment details affect uniformity of the strain field inside the attachment points. The computational studies confirm that increasing the number of attachment points increases the size of the area that experiences sensibly uniform strain (defined here as the central sample region where the ratio of principal strains E11/E22<1.10), and that the strains experienced in this region are less than nominal strains based on attachment point movement. Uniformity of the strain field improves substantially when the attachment points span a wide zone along each edge. Subtle irregularities in attachment point positioning can significantly degrade strain field uniformity. In contrast, details of the apron, the region outside of the attachment points, have little effect on the interior strain field. When nonlinear properties consistent with those found in human sclera are used, similar results are found. Experiments were conducted on 6×6 mm talc-sprinkled rubber specimens loaded using wire “rakes.” Points on a grid having 12×12 bays were tracked, and a detailed strain map was constructed. A finite element model based on the actual geometry of an experiment having an off-pattern rake tine gave strain patterns that matched to within 4.4%. Finally, simulations using nonequibiaxial strains indicated that the strain field uniformity was more sensitive to sample attachment details for the nonequibiaxial case as compared to the equibiaxial case. Specimen design and attachment were found to significantly affect the uniformity of the strain field produced in biaxial tests. Practical guidelines were offered for design and mounting of biaxial test specimens. The issues addressed here are particularly relevant as specimens become smaller in size.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司