A Well-Posed, Embedded Constraint Representation of Joint Moments From Kinesiological Measurements

Author:

Dariush Behzad1,Hemami Hooshang2,Parnianpour Mohamad3

Affiliation:

1. Honda R&D Americas, Inc., Fundamental Research Laboratories, 800 California St., Suite 300, Mountain View, CA 94041

2. Department of Electrical Engineering, The Ohio State University, 2015 Neil Ave., Columbus, OH 43210-1272

3. Department of Industrial, Welding and Systems Engineering, The Ohio State University, 1971 Neil Ave., Columbus, OH 43210-1271

Abstract

Joint moment estimation using the traditional inverse dynamics analysis presents two challenging problems, which limit its reliability. First, the quality of the computed moments depends directly on unreliable estimates of the segment accelerations obtained numerically by differentiating noisy marker measurements. Second, the representation of joint moments from combined video and force plate measurements belongs to a class of ill-posed problems, which does not possess a unique solution. This paper presents a well-posed representation derived from an embedded constraint equation. The proposed method, referred to as the embedded constraint representation (ECR), provides unique moment estimates, which satisfy all measurement constraints and boundary conditions and require fewer acceleration components than the traditional inverse dynamics method. Specifically, for an n-segment open chain planar system, the ECR requires n−3 acceleration components as compared to 3n−1 components required by the traditional (from ground up) inverse dynamics analysis. Based on a simulated experiment using a simple three-segment model, the precision of the ECR is evaluated at different noise levels and compared to the traditional inverse dynamics technique. At the lowest noise levels, the inverse dynamics method is up to 50 percent more accurate while at the highest noise levels the ECR method is up to 100 percent more accurate. The ECR results over the entire range of noise levels reveals an average improvement on the order 20 percent in estimating the moments distal to the force plate and no significant improvement in estimating moments proximal to the force plate. The new method is particularly advantageous in a combined video, force plate, and accelerometery sensing strategy. [S0148-0731(00)01904-X]

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3