Affiliation:
1. Department of Bioengineering, University of Pittsburgh, Room 749, Benedum Hall, 3700 Ohara St., Pittsburgh, PA 15261
Abstract
A limitation in virtually all planar biaxial studies of soft tissues has been the inability to include the effects of in-plane shear. This is due to the inability of current mechanical testing devices to induce a state of in-plane shear, due to the added cost and complexity. In the current study, a straightforward method is presented for planar biaxial testing that induces a combined state of in-plane shear and normal strains. The method relies on rotation of the test specimen’s material axes with respect to the device axes and on rotating carriages to allow the specimen to undergo in-plane shear freely. To demonstrate the method, five glutaraldehyde treated bovine pericardium specimens were prepared with their preferred fiber directions (defining the material axes) oriented at 45 deg to the device axes to induce a maximum shear state. The test protocol included a wide range of biaxial strain states, and the resulting biaxial data re-expressed in material axes coordinate system. The resulting biaxial data was then fit to the following strain energy function W: W=c/2[exp(A1E′112+A2E′222+2A3E′11E′22+A4E′122+2A5E′11E′12+2A6E′22E′12)−1]where E′ij is the Green’s strain tensor in the material axes coordinate system and c and Ai are constants. While W was able to fit the data very well, the constants A5 and A6 were found not to contribute significantly to the fit and were considered unnecessary to model the shear strain response. In conclusion, while not able to control the amount of shear strain independently or induce a state of pure shear, the method presented readily produces a state of simultaneous in-plane shear and normal strains. Further, the method is very general and can be applied to any anisotropic planar tissue that has identifiable material axes.
Subject
Physiology (medical),Biomedical Engineering
Reference26 articles.
1. Billiar
K.
, and SacksM., 1997, “A method to quantify the fiber kinematics of planar tissues under biaxial stretch,” Journal of Biomechanics, 30(7): 753–756.
2. Billiar, K., and Sacks, M., 1998, “Biaxial mechanics of fresh and glutaraldehyde treated porcine aortic valve cusps,” ASME JOURNAL OF BIOMECHANICAL ENGINEERING, submitted.
3. Brossollet
L. J.
, and VitoR. P., 1996, “A new approach to mechanical testing and modeling of biological tissues, with application to blood vessels,” ASME JOURNAL OF BIOMECHANICAL ENGINEERING, 118: 433–439.
4. Chew
P. H.
, YinF. C. P., and ZegerS. L., 1986, “Biaxial Stress-Strain Properties of Canine Pericardium,” Journal of Molecular and Cell Cardiology, 18: 567–578.
5. Choi
H. S.
, and VitoR. P., 1990, “Two Dimensional Stress-Strain Relationship for Canine Pericardium,” ASME JOURNAL OF BIOMECHANICAL ENGINEERING, 112: 153–159.
Cited by
111 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献