Abstract

The dynamic behavior of a solid oxide fuel cell gas turbine hybrid system (SOFC/GT) from both open and closed loop transients in response to sudden changes in fuel composition was experimentally investigated. A pilot-scale (200–700 kW) hybrid facility available at the U.S. Department of Energy, National Energy Technology Laboratory was used to perform the experiments using a combination of numerical models and actual equipment. In the open loop configuration, the turbine speed was driven by the thermal effluent fed into the gas turbine system, where the thermal effluent was determined by the feedforward fuel cell control system. However, in the closed loop configuration, a load-based speed control system was used to maintain the turbine speed constant at 40,500 rpm by adjusting the load on the turbine, in addition to the implementation of the fuel cell system control. The open loop transient response showed that the impacts of fuel composition changes on key process variables, such as fuel cell thermal effluent, turbine speed, and cathode feed stream conditions, in the SOFC/GT systems were propagated over the course of the test, except for the cathode inlet temperature. The trajectories of the aforementioned variables are discussed in this paper to better understand the resulting mitigation/propagation behaviors. This will help lead to the development of novel control strategies to mitigate the negative impacts experienced during fuel composition transients of SOFC/GT systems.

Publisher

ASME International

Subject

Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering

Reference14 articles.

1. Avoiding Compressor Surge During Emergency Shut-Down Hybrid Turbine Systems;ASME J. Eng. Gas Turbines Power,2013

2. Tucker, D., Tsai, A., Jablonski, P., Hughes, D. O., Haynes, C. L., and Sellers, J., 2010, “Initial Transient Response During Fuel Cell Turbine Hybrid System Startup,” International Colloquium on Environmentally Preferred Advanced Power Generation (ICEPAG), Costa Mesa, CA, Feb. 9–11, Paper No. ICEPAG2010-3414.

3. Tucker, D., Liese, E., and Gemmen, R., 2009, “Determination of the Operating Envelope for a Direct Fired Fuel Cell Turbine Hybrid Using Hardware Based Simulation,” International Colloquium on Environmentally Preferred Advanced Power Generation (ICEPAG), Newport Beach, CA, Feb. 10–12, Paper No. ICEPAG2009-1021.https://www.osti.gov/scitech/biblio/1015479

4. SOFC Lifetime Assessment in Gas Turbine Hybrid Power Systems;ASME J. Fuel Cell Sci. Technol.,2014

5. Fuel Flexibility in Power Generation by Solid Oxide Fuel Cells;J. Solid State Ionics,2002

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3