Experimental Investigation of Tip Clearance Flow in a Transonic Compressor With and Without Plasma Actuators

Author:

Saddoughi S.1,Bennett G.1,Boespflug M.1,Puterbaugh S. L.2,Wadia A. R.3

Affiliation:

1. GE Global Research, Niskayuna, NY 12309 e-mail:

2. AFRL/RQTT, Wright-Patterson AFB, OH 45433 e-mail:

3. Fellow ASME GE Aviation, Cincinnati, OH 45215 e-mail:

Abstract

Blade tip losses represent a major performance penalty in low aspect ratio transonic compressors. This paper reports on the experimental evaluation of the impact of tip clearance with and without plasma actuator flow control on performance of an U.S. Air Force-designed low aspect ratio, high radius ratio single-stage transonic compressor rig. The detailed stage performance measurements without flow control at three clearance levels, classified as small, medium, and large, are presented. At design-speed, increasing the clearance from small to medium resulted in a stage peak efficiency drop of almost six points with another four point drop in efficiency with the large clearance (LC). Comparison of the speed lines at high-speed show significantly lower pressure rise with increasing tip clearance, the compressor losing 8% stall margin (SM) with medium clearance (MC) and an additional 1% with the LC. Comparison of the stage exit radial profiles of total pressure and adiabatic efficiency at both part-speed and design-speed and with throttling are presented. Tip clearance flow-control was investigated using dielectric barrier discharge (DBD) type plasma actuators. The plasma actuators were placed on the casing wall upstream of the rotor leading edge and the compressor mapped from part-speed to high-speed at three clearances with both axial and skewed configurations at six different frequency levels. The plasma actuators did not impact steady state performance. A maximum SM improvement of 4% was recorded in this test series. The LC configuration benefited the most with the plasma actuators. Increased voltage provided more SM improvement. Plasma actuator power requirements were almost halved going from continuous operation to pulsed plasma. Most of the improvement with the plasma actuators is attributed to the reduction in unsteadiness of the tip clearance vortex near-stall resulting in additional reduction in flow prior to stall.

Publisher

ASME International

Subject

Mechanical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3