Modeling the Human Tibiofemoral Joint Using Ex Vivo Determined Compliance Matrices

Author:

Lamberto Giuliano12,Richard Vincent3,Dumas Raphaël3,Valentini Pier Paolo4,Pennestrì Ettore5,Lu Tung-Wu6,Camomilla Valentina7,Cappozzo Aurelio7

Affiliation:

1. Department of Movement, Human, and Health Sciences, Università degli Studi di Roma—Foro Italico, Piazza Lauro de Bosis 6, Rome 00194, Italy;

2. Department of Mechanical Engineering, INSIGNEO Institute for In Silico Medicine, University of Sheffield, Mappin Street, Sheffield S1 3JD, UK e-mail:

3. University of Lyon, Université Claude Bernard Lyon 1, IFSTTAR, UMR_T9406, LBMC, Lyon F69622, France e-mail:

4. Department of Enterprise Engineering “Mario Lucertini,” Università degli Studi di Roma—Tor Vergata, Via del Politecnico 1, Rome 00133, Italy e-mail:

5. Mem. ASME Department of Enterprise Engineering “Mario Lucertini,” Università degli Studi di Roma—Tor Vergata, Via del Politecnico 1, Rome 00133, Italy e-mail:

6. Institute of Biomedical Engineering and Department of Orthopaedic Surgery, National Taiwan University, No. 1, Section 4, Roosevelt Road, Taipei 106, Taiwan e-mail:

7. Department of Movement, Human, and Health Sciences, Università degli Studi di Roma—Foro Italico, Piazza Lauro de Bosis 6, Rome 00194, Italy e-mail:

Abstract

Several approaches have been used to devise a model of the human tibiofemoral joint for embedment in lower limb musculoskeletal models. However, no study has considered the use of cadaveric 6 × 6 compliance (or stiffness) matrices to model the tibiofemoral joint under normal or pathological conditions. The aim of this paper is to present a method to determine the compliance matrix of an ex vivo tibiofemoral joint for any given equilibrium pose. Experiments were carried out on a single ex vivo knee, first intact and, then, with the anterior cruciate ligament (ACL) transected. Controlled linear and angular displacements were imposed in single degree-of-freedom (DoF) tests to the specimen, and the resulting forces and moments were measured using an instrumented robotic arm. This was done starting from seven equilibrium poses characterized by the following flexion angles: 0 deg, 15 deg, 30 deg, 45 deg, 60 deg, 75 deg, and 90 deg. A compliance matrix for each of the selected equilibrium poses and for both the intact and ACL-deficient specimen was calculated. The matrix, embedding the experimental load–displacement relationship of the examined DoFs, was calculated using a linear least squares inversion based on a QR decomposition, assuming symmetric and positive-defined matrices. Single compliance matrix terms were in agreement with the literature. Results showed an overall increase of the compliance matrix terms due to the ACL transection (2.6 ratio for rotational terms at full extension) confirming its role in the joint stabilization. Validation experiments were carried out by performing a Lachman test (the tibia is pulled forward) under load control on both the intact and ACL-deficient knee and assessing the difference (error) between measured linear and angular displacements and those estimated using the appropriate compliance matrix. This error increased nonlinearly with respect to the values of the load. In particular, when an incremental posterior–anterior force up to 6 N was applied to the tibia of the intact specimen, the errors on the estimated linear and angular displacements were up to 0.6 mm and 1.5 deg, while for a force up to 18 N, the errors were 1.5 mm and 10.5 deg, respectively. In conclusion, the method used in this study may be a viable alternative to characterize the tibiofemoral load-dependent behavior in several applications.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3