Author:
Hu Chih-Chung,Lu Tung-Wu,Chen Sheng-Chang
Abstract
Abstract
Background
Predictions of the forces transmitted by the redundant force-bearing structures in the knee are often performed using optimization methods considering only moment equipollence as a result of simplified knee modeling without ligament contributions. The current study aimed to investigate the influence of model complexity (with or without ligaments), problem formulation (moment equipollence with or without force equipollence) and optimization criteria on the prediction of the forces transmitted by the force-bearing structures in the knee.
Methods
Ten healthy young male adults walked in a gait laboratory while their kinematic and ground reaction forces were measured simultaneously. A validated 3D musculoskeletal model of the locomotor system with a knee model that included muscles, ligaments and articular surfaces was used to calculate the joint resultant forces and moments, and subsequently the forces transmitted in the considered force-bearing structures via optimization methods. Three problem formulations with eight optimization criteria were evaluated.
Results
Among the three problem formulations, simultaneous consideration of moment and force equipollence for the knee model with ligaments and articular contacts predicted contact forces (first peak: 3.3-3.5 BW; second peak: 3.2-4.2 BW; swing: 0.3 BW) that were closest to previously reported theoretical values (2.0-4.0 BW) and in vivo data telemetered from older adults with total knee replacements (about 2.8 BW during stance; 0.5 BW during swing). Simultaneous consideration of moment and force equipollence also predicted more physiological ligament forces (< 1.0 BW), which appeared to be independent of the objective functions used. Without considering force equipollence, the calculated contact forces varied from 1.0 to 4.5 BW and were as large as 2.5 BW during swing phase; the calculated ACL forces ranged from 1 BW to 3.7 BW, and those of the PCL from 3 BW to 7 BW.
Conclusions
Model complexity and problem formulation affect the prediction of the forces transmitted by the force-bearing structures at the knee during normal level walking. Inclusion of the ligaments in a knee model enables the simultaneous consideration of equations of force and moment equipollence, which is required for accurately estimating the contact and ligament forces, and is more critical than the adopted optimization criteria.
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging,Biomedical Engineering,General Medicine,Biomaterials,Radiological and Ultrasound Technology
Reference46 articles.
1. Zavatsky A, O'Connor JJ: A Model of human knee ligaments in the sagittal plane: part 1: response to passive flexion. P I Mech Eng H 1992, 206(3):125–134. 10.1243/PIME_PROC_1992_206_280_02
2. Lu T, O'Connor JJ: Lines of action and moment arms of the major force-bearing structures crossing the human knee joint: comparison between theory and experiment. J Anat 1996, 189(Pt 3):575–585.
3. Taylor ME, Tanner KE, Freeman MR, Yettram AL: Stress and strain distribution within the intact femur: compression or bending? Med Eng Phys 1996, 18(2):122–131. 10.1016/1350-4533(95)00031-3
4. English TA, Kilvington M: In vivo records of hip loads using a femoral implant with telemetric output (a preliminary report). J Biomed Eng 1979, 1(2):111–115. 10.1016/0141-5425(79)90066-9
5. Heinlein B, Kutzner I, Graichen F, Bender A, Rohlmann A, Halder AM, Beier A, Bergmann G: ESB Clinical Biomechanics Award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6–10 months. Clin Biomech 2009, 24(4):315–326. 10.1016/j.clinbiomech.2009.01.011
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献