Design Framework and Clinical Evaluation of a Passive Hydraulic Patient Simulator for Biceps Spasticity Assessment Training

Author:

Pei Yinan1,Ewoldt Randy H.1,Zallek Christopher M.2,Hsiao-Wecksler Elizabeth T.1

Affiliation:

1. Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 1206 West Green Street, Urbana, IL 61801

2. Department of Neurology, OSF HealthCare Illinois Neurological Institute, 200 E Pennsylvania Avenue, Peoria, IL 61603

Abstract

Abstract This article presents the framework for developing a passive (unpowered) mechanical training simulator for replication of biceps spasticity to complement current clinical assessment training. The passive training simulator was developed to mimic three main behavioral features of spasticity, i.e., abnormal muscle tone, catch-release behavior, and range of motion (ROM) reduction. The simulator can replicate varied levels of spasticity (Modified Ashworth Scale (MAS) levels 0–4) using a combination of three adjustable mechanical design features, i.e., resistance level, catch angle, and ROM selectors. Bench-top evaluation examined the performance of individual mechanical design features, as well as their combined performance. Spastic muscle resistance profiles generated by the simulator qualitatively agreed with the clinical descriptions of spasticity in the MAS. Mean peak simulated resistive torque fell within the clinical measures from actual spasticity patients for MAS 1–4, but was lower for MAS 0 (0.9, 3.5, 4.2, 6.9, 9.8 Nm for MAS 0–4, respectively). Seven clinicians were invited to validate the simulator performance. They were asked to identify the simulated MAS level during a blinded assessment and to score the realism of each simulation feature using a five-point scale, where 3 was “about right,” during a disclosed assessment. The mean percent agreement of clinicians’ judgments was 76 ± 12%. The mean realism score throughout MAS 0–4 were 2.82 ± 0.15. Preliminary results suggested good potential for this simulator in helping future healthcare practitioners learn and practice the basics of spasticity assessment.

Publisher

ASME International

Subject

Mechanical Engineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3