Regularization-Free Strain Mapping in Three Dimensions, With Application to Cardiac Ultrasound

Author:

Boyle John J.1,Soepriatna Arvin2,Damen Frederick2,Rowe Roger A.3,Pless Robert B.4,Kovacs Attila5,Goergen Craig J.2,Thomopoulos Stavros6,Genin Guy M.7

Affiliation:

1. Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO 63130; Department of Orthopaedic Surgery, Columbia University, Black Building 1406, 650 W 168 Street, New York, NY 10032

2. Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, Room 3025, West Lafayette, IN 47907

3. Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, Jolley Hall, CB 1185, 1 Brookings Drive, St. Louis, MO 63130

4. Department of Computer Science, George Washington University, 800 22nd Street NW Room 4000, Washington, DC 20052

5. Department of Internal Medicine, Cardiovascular Division, Washington University School of Medicine, 660 S. Euclid Avenue, CB 8086, St. Louis, MO 63110

6. Department of Orthopaedic Surgery, Columbia University, New York, NY 10032; Department of Biomedical Engineering, Columbia University, Black Building 1408, 650 W 168 Street, New York, NY 10032

7. Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO 63130; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, MO 63130; NSF Science and Technology Center for Engineering Mechanobiology, Washington University in St. Louis, Green Hall, CB 1099, 1 Brookings Drive, St. Louis, MO 63130

Abstract

Abstract Quantifying dynamic strain fields from time-resolved volumetric medical imaging and microscopy stacks is a pressing need for radiology and mechanobiology. A critical limitation of all existing techniques is regularization: because these volumetric images are inherently noisy, the current strain mapping techniques must impose either displacement regularization and smoothing that sacrifices spatial resolution, or material property assumptions that presuppose a material model, as in hyperelastic warping. Here, we present, validate, and apply the first three-dimensional (3D) method for estimating mechanical strain directly from raw 3D image stacks without either regularization or assumptions about material behavior. We apply the method to high-frequency ultrasound images of mouse hearts to diagnose myocardial infarction. We also apply the method to present the first ever in vivo quantification of elevated strain fields in the heart wall associated with the insertion of the chordae tendinae. The method shows promise for broad application to dynamic medical imaging modalities, including high-frequency ultrasound, tagged magnetic resonance imaging, and confocal fluorescence microscopy.

Funder

American Heart Association

National Heart, Lung, and Blood Institute

National Institute of Biomedical Imaging and Bioengineering

National Institute of Diabetes and Digestive and Kidney Diseases

National Science Foundation

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering