In Silico Performance of a Recellularized Tissue-Engineered Transcatheter Aortic Valve

Author:

Noble Christopher1,Choe Joshua1,Uthamaraj Susheil2,Deherrera Milton1,Lerman Amir1,Young Melissa3

Affiliation:

1. Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905 e-mail:

2. Division of Engineering, Mayo Clinic, Rochester, MN 55905 e-mail:

3. Department of Cardiovascular Medicine, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905 e-mail:

Abstract

Commercially available heart valves have many limitations, such as a lack of remodeling, risk of calcification, and thromboembolic problems. Many state-of-the-art tissue-engineered heart valves (TEHV) rely on recellularization to allow remodeling and transition to mechanical behavior of native tissues. Current in vitro testing is insufficient in characterizing a soon-to-be living valve due to this change in mechanical response; thus, it is imperative to understand the performance of an in situ valve. However, due to the complex in vivo environment, this is difficult to accomplish. Finite element (FE) analysis has become a standard tool for modeling mechanical behavior of heart valves; yet, research to date has mostly focused on commercial valves. The purpose of this study has been to evaluate the mechanical behavior of a TEHV material before and after 6 months of implantation in a rat subdermis model. This model allows the recellularization and remodeling potential of the material to be assessed via a simple and inexpensive means prior to more complex ovine orthotropic studies. Biaxial testing was utilized to evaluate the mechanical properties, and subsequently, constitutive model parameters were fit to the data to allow mechanical performance to be evaluated via FE analysis of a full cardiac cycle. Maximum principal stresses and strains from the leaflets and commissures were then analyzed. The results of this study demonstrate that the explanted tissues had reduced mechanical strength compared to the implants but were similar to the native tissues. For the FE models, this trend was continued with similar mechanical behavior in explant and native tissue groups and less compliant behavior in implant tissues. Histology demonstrated recellularization and remodeling although remodeled collagen had no clear directionality. In conclusion, we observed successful recellularization and remodeling of the tissue giving confidence to our TEHV material; however, the mechanical response indicates the additional remodeling would likely occur in the aortic/pulmonary position.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference39 articles.

1. Valvular Heart Disease: The Next Cardiac Epidemic;Heart,2011

2. Contemporary Management of Aortic Stenosis: Surgical Aortic Valve Replacement Remains the Gold Standard;Heart,2012

3. Heart Valve Tissue Engineering;Circ. Res.,2005

4. Bioengineering Challenges for Heart Valve Tissue Engineering;Annu. Rev. Biomed. Eng.,2009

5. Tissue Decellularization by Activation of Programmed Cell Death;Biomaterials,2013

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3