Finite Element-Based Pelvic Injury Metric Creation and Validation in Lateral Impact for a Human Body Model

Author:

Weaver Caitlin M.12,Baker Alexander M.3,Davis Matthew L.4,Miller Anna N.5,Stitzel Joel D.6

Affiliation:

1. Mem. ASME Wake Forest University School of Medicine, Virginia Tech-Wake Forest University Center for Injury Biomechanics, 575 N. Patterson Avenue, Suite 120, Winston-Salem, NC 27101;

2. Soldier Protection Sciences Branch, U.S. Army Research Laboratory, RDRL-WMP-B, Aberdeen Proving Ground, Aberdeen, MD 21005 e-mail:

3. Wake Forest University School of Medicine, Virginia Tech-Wake Forest University Center for Injury Biomechanics, 575 N. Patterson Avenue, Suite 120, Winston-Salem, NC 27101 e-mail:

4. Mem. ASME Wake Forest University School of Medicine, Virginia Tech-Wake Forest University Center for Injury Biomechanics, 575 N. Patterson Avenue, Suite 120, Winston-Salem, NC 27101 e-mail:

5. Department of Orthopedic Surgery, Washington University, P.O. Box 8233, 660 S. Euclid Avenue, St. Louis, MO 63110 e-mail:

6. Wake Forest University School of Medicine, Virginia Tech-Wake Forest University Center for Injury Biomechanics, 575 N. Patterson Avenue, Suite 120 Winston-Salem, NC 27101 e-mail:

Abstract

Pelvic fractures are serious injuries resulting in high mortality and morbidity. The objective of this study is to develop and validate local pelvic anatomical, cross section-based injury risk metrics for a finite element (FE) model of the human body. Cross-sectional instrumentation was implemented in the pelvic region of the Global Human Body Models Consortium (GHBMC M50-O) 50th percentile detailed male FE model (v4.3). In total, 25 lateral impact FE simulations were performed using input data from cadaveric lateral impact tests performed by Bouquet et al. The experimental force-time data were scaled using five normalization techniques, which were evaluated using log rank, Wilcoxon rank sum, and correlation and analysis (CORA) testing. Survival analyses with Weibull distribution were performed on the experimental peak force (scaled and unscaled) and the simulation test data to generate injury risk curves (IRCs) for total pelvic injury. Additionally, IRCs were developed for regional injury using cross-sectional forces from the simulation results and injuries documented in the experimental autopsies. These regional IRCs were also evaluated using the receiver operator characteristic (ROC) curve analysis. Based on the results of all the evaluation methods, the equal stress equal velocity (ESEV) and ESEV using effective mass (ESEV-EM) scaling techniques performed best. The simulation IRC shows slight under prediction of injury in comparison to these scaled experimental data curves. However, this difference was determined not to be statistically significant. Additionally, the ROC curve analysis showed moderate predictive power for all regional IRCs.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference39 articles.

1. The Epidemiology of Pelvic Ring Fractures: A Population-Based Study;J. Trauma Inj. Infect. Crit. Care,2007

2. The Increasing Incidence of Severe Pelvic Injury in Motor Vehicle Collisions;Injury,2004

3. Risk Factors for Pelvic Fracture in Lateral Impact Motor Vehicle Crashes;Accid. Anal. Prev.,2008

4. Dischinger, P. C., Read, K. M., Kufera, J. A., Kerns, T. J., Burch, C. A., Jawed, N., Ho, S. M., and Burgess, A. R., 2004, “Consequences and Costs of Lower Extremity Injuries,” 48th Annual Association for the Advancement of Automotive Medicine, Key Biscayne, FL, Sept. 13–15, pp. 339–358.

5. Classification and Biomechanics of Pelvic Ring Injuries;Operative Tech. Orthop.,1997

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3