Affiliation:
1. Department of Mechanical and Industrial Engineering, Louisiana Tech University, Ruston, LA 71272
Abstract
Natural convection heat transfer was investigated in a scaled test facility of a Trombe wall geometry. A silicone oil was employed as the convecting medium to obtain large Rayleigh numbers (up to 1.5 × 1010, based on enclosure height) characteristic of full-scale Trombe wall in a passive solar building. The main objectives were to study effects of Trombe wall nonisothermality and location on heat transfer, fluid temperature and fluid flow patterns. As expected, Nusselt numbers were slightly larger on the Trombe wall space side than on the living space side. Nusselt numbers increased slightly as the mass transfer gaps in the Trombe wall were increased. The results were verified, for the zero gap case, by comparing with previous studies. Physical understanding of the convection process was enhanced by flow visualization data. The information obtained should be useful to designers in optimizing overall building performance for passive solar heating.
Subject
Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment
Cited by
31 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献