Affiliation:
1. Rochester Institute of Technology, Rochester, NY
Abstract
An approach towards practical application of microchannel cooling system is necessary as the demand of high power density devices is increasing. Colgan et. al. [1] have designed a unit known as Single Chip Module (SCM) by considering the practical issues for packaging a microchannel cooling system with a microelectronic device. The performance of the SCM has already been investigated by using water as working fluid by Colgan et. al. [1]. Considering the actual working conditions, water cannot be used in electronic devices as the working fluid because any leakage may lead to system damage. Alternative fluids like refrigerants were considered. In this research, the performance of SCM has been studied by using refrigerant R-123 as working fluid and compared with water cooled system. Cooling of 83.33 W/cm2 has been achieved for a powered area of 3 cm2 by maintaining chip temperature of 60°C. The heat transfer co-efficient obtained at a flowrate of 0.7 lpm was 34.87 kW/m2-K. The results obtained indicate that from a thermal viewpoint, R-123 can be considered as working fluid for microelectronic cooling devices.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献