Affiliation:
1. Department of Mechanical Engineering, McMaster University, Hamilton, Ontario, Canada L8S 4L7
2. Foster Wheeler Power Group, Inc., Perryville Corporate Park, Clinton, NJ, 08809-4000
Abstract
Experimental laboratory research was performed to study the effect of test section width on the magnitude of acoustic resonance generated in a small pitch ratio staggered tube bank. Three different test section widths were studied: 505mm, 714mm, and 953mm. The results for acoustic resonance were compared to the tube bank data of Blevins and Bressler (1993, J. Sound Vib., 164(3), pp. 503–533), Ziada, Bolleter, and Chen (1984, ASME Symposium on Flow-Induced Vibrations, ASME, New York, Vol. 2, pp. 227–242); Ziada, Oengören, and Buhlmann (1989, J. Fluids and Struct., 3, pp. 293–324), and Fitzpatrick and Donaldson (1977, ASME J. Fluids Eng., 99, pp. 681–686). The present study showed that test-section width may be a significant factor in determining the maximum acoustic pressures generated by the flow. In particular, the simple relationship between maximum acoustic pressure and input energy parameter derived by Blevins and Bressler was not a reliable predictor for the array studied and will likely underpredict the maximum acoustic pressures in the lower modes of practical heat exchangers.
Subject
Mechanical Engineering,Mechanics of Materials,Safety, Risk, Reliability and Quality
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献