Affiliation:
1. Carleton University, Ottawa, ON, Canada
Abstract
Experiments were conducted to determine the effects of vaneless diffuser radius ratio on the occurrence of self-excited flow oscillations in a centrifugal compression system. Analysis of the results indicated the successive occurrence of two types of diffuser rotating pressure patterns as the flow rate in the system was gradually decreased. The rotational speed of the latter pattern was higher than that of the initial pattern and both speeds varied inversely with diffuser radius ratio. The critical flow angle at which each pattern was first observed increased with diffuser radius ratio. However, for diffuser radius ratio equal to and larger than 1.75 the rate of change of the critical angle with radius ratio decreased significantly. The results also showed that the minimum diffuser radius ratio necessary for self excitation of each pattern were different. Occurrence of two rotating pressure patterns confirms analytical results presented in a previous investigation.
Publisher
American Society of Mechanical Engineers
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献