Affiliation:
1. Thermo-Fluid Systems UTC, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, Surrey GU2 7XH, UK e-mail:
Abstract
Previous studies have indicated some differences between steady computational fluid dynamics (CFD) predictions of flow in a rotor–stator disk cavity with rotating bolts compared to measurements. Recently, time-dependent CFD simulations have revealed the unsteadiness present in the flow and have given improved agreement with measurements. In this paper, unsteady Reynolds averaged Navier–Stokes (URANS) 360 deg model CFD calculations of a rotor–stator cavity with rotor bolts were performed in order to better understand the flow and heat transfer within a disk cavity previously studied experimentally by other workers. It is shown that the rotating bolts generate unsteadiness due to wake shedding which creates time-dependent flow patterns within the cavity. At low throughflow conditions, the unsteady flow significantly increases the average disk temperature. A systematic parametric study is presented giving insight into the influence of number of bolts, mass flow rate, cavity gap ratio, and the bolts-to-shroud gap ratio on the time-dependent flow within the cavity.
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献