Estimation of the Daily Utilizability of a Flat Plate Solar Collector for Different Climatic Zones in Algeria

Author:

Smaili K.1,Kasbadji Merzouk N.2,Merzouk M.3,Boukenoui R.4

Affiliation:

1. University of Blida 1 Surface Treatment and Materials Laboratory (LTSM), Faculty of Technology;, Department of Renewable Energies, Faculty of Technology, , Blida 09000 , Algeria

2. Renewable Energy Development Center, CDER Solar Equipment Development Unit, UDES, , Tipaza 42004 , Algeria

3. University of Blida 1 Department of Renewable Energies, Faculty of Technology, , Blida 09000 , Algeria

4. University of Blida 1 SET Laboratory, Department of Renewable Energies, Faculty of Technology, , Blida 09000 , Algeria

Abstract

Abstract The essential aim of this study is to estimate the daily utilizability and useful energy of a flat-plate solar collector in Algeria for different climatic zones. For this purpose, a program based on Klein’s method was developed to estimate the daily utilizability and the useful energy characterized by the optical efficiency and the global loss coefficient that are equal to 0.72 and 7.9 W/m2K, respectively. The seasonal potentials of the whole studied zones are represented by geographical maps; then, a parametric study is performed to see the influence of the inlet temperature of the heat transfer fluid, the optical efficiency, and the global coefficient losses on the average utilizability per month for each site. Subsequently, the utilizability variations considering different sites and during various months are analyzed in terms of the average temperature of the heat transfer fluid, the optical efficiency, and the coefficient of global losses. The results show that the usable potential produced by this type of solar collector is 1500–1700 MJ/m2 in climatic zones E5 (Tanegrouft), E4 (Sahara), and E3 (Pre-Sahara) and is 1300 MJ/m2 in climatic zones E2 (Highlands) and E1 (Coastal) during the summer season. While for the winter season, the usable potential is 500–700 MJ/m2 in climatic zones E1 and E2, and 700–900 MJ/m2 in E3, E4, and E5, which can be considered the most favorable zones for the conversion of the available solar energy into thermal one through the flat-plate solar collector. The study of the effect on the system performance considering usability has shown that the effects of the overall loss coefficient are more significant compared to optical efficiency.

Publisher

ASME International

Subject

Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment

Reference44 articles.

1. Calculation of Flat—Plate Collector Utilizability;Klein;Sol. Energy,1978

2. Whillier, A. , 1953, “Solar Energy Collection and Its Utilization for House Heating,” Ph.D. thesis, University of the Witwatersrand, Cambridge, MA. https://dspace.mit.edu/handle/1721.1/11922?show=full

3. The Long—Term Average Performance of Flat—Plate Solar Energy Collectors;Liu;Sol. Energy,1963

4. Simple Procedure for Predicting Long—Term Average Performance of None Concentrating and Concentrating Solar Collectors;Collares-Pereira;Sol. Energy,1979

5. A General Design Method for Closed—Loop Solar Energy Systems;Klein;Sol. Energy,1979

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3