Dissection Properties of the Human Aortic Media: An Experimental Study

Author:

Sommer Gerhard1,Gasser T. Christian2,Regitnig Peter3,Auer Martin1,Holzapfel Gerhard A.4

Affiliation:

1. Institute for Biomechanics, Graz University of Technology, 8010 Graz, Austria

2. Department of Solid Mechanics, Royal Institute of Technology (KTH), 100 44 Stockholm, Sweden

3. Institute of Pathology, Medical University Graz, 8036 Graz, Austria

4. Institute for Biomechanics, Centre for Biomedical Engineering, Graz University of Technology, 8010 Graz, Austria; Department of Solid Mechanics, Royal Institute of Technology (KTH), 100 44 Stockholm, Sweden

Abstract

Aortic dissection occurs frequently and is clinically challenging; the underlying mechanics remain unclear. The present study investigates the dissection properties of the media of 15 human abdominal aortas (AAs) by means of direct tension tests (n=8) and peeling tests (n=12). The direct tension test demonstrates the strength of the media in the radial direction, while the peeling test allows a steady-state investigation of the dissection propagation. To explore the development of irreversible microscopic changes during medial dissection, histological images (n=8) from four AAs at different peeling stages are prepared and analyzed. Direct tension tests of coin-shaped medial specimens result in a radial failure stress of 140.1±15.9kPa (mean±SD, n=8). Peeling tests of rectangular-shaped medial strips along the circumferential and axial directions provide peeling force∕width ratios of 22.9±2.9mN∕mm(n=5) and 34.8±15.5mN∕mm(n=7); the related dissection energies per reference area are 5.1±0.6mJ∕cm2 and 7.6±2.7mJ∕cm2, respectively. Although student’s t-tests indicate that force∕width values of both experimental tests are not significantly different (α=0.05, p=0.125), the strikingly higher resisting force∕width obtained for the axial peeling tests is perhaps indicative of anisotropic dissection properties of the human aortic media. Peeling in the axial direction of the aorta generates a remarkably “rougher” dissection surface with respect to the surface generated by peeling in the circumferential direction. Histological analysis of the stressed specimens reveals that tissue damage spreads over approximately six to seven elastic laminae, which is about 15–18% of the thickness of the abdominal aortic media, which forms a pronounced cohesive zone at the dissection front.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference45 articles.

1. Wall Stress as a Possible Mechanism for the Development of Transverse Intimal Tears in Aortic Dissections;Thubrikar;J. Med. Eng. Technol.

2. Clinical Diagnostic, and Management Perspectives of Aortic Dissection;Khan;Chest

3. Aortic Dissection Following Coronary Artery Bypass Surgery: Diagnosis by CT;Archer;Cardiovasc. Intervent Radiol.

4. Rupture of the Aorta Following road Traffic Accidents in the United Kingdom 1992–1999. The Results of the Co-Operative Crash Injury Study;Richens;Eur. J. Cardiothorac Surg.

5. Spiral CT Aortography: An Efficient Technique for the Diagnosis of Traumatic Aortic Injury;Wicky;Eur. Radiol.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3