In Vitro Quantification of Time Dependent Thrombus Size Using Magnetic Resonance Imaging and Computational Simulations of Thrombus Surface Shear Stresses

Author:

Taylor Joshua O.12,Witmer Kory P.3,Neuberger Thomas43,Craven Brent A.53,Meyer Richard S.2,Deutsch Steven2,Manning Keefe B.16

Affiliation:

1. Department of Bioengineering, The Pennsylvania State University, University Park, PA 16802;

2. Applied Research Laboratory, The Pennsylvania State University, State College, PA 16803

3. Department of Bioengineering, The Pennsylvania State University, University Park, PA 16802

4. Huck Institutes of the Life Sciences, The Pennsylvania State University, University Park, PA 16802;

5. Applied Research Laboratory, The Pennsylvania State University, State College, PA 16803;

6. Department of Surgery, The Penn State College of Medicine, Hershey, PA 17033 e-mail:

Abstract

Thrombosis and thromboembolization remain large obstacles in the design of cardiovascular devices. In this study, the temporal behavior of thrombus size within a backward-facing step (BFS) model is investigated, as this geometry can mimic the flow separation which has been found to contribute to thrombosis in cardiac devices. Magnetic resonance imaging (MRI) is used to quantify thrombus size and collect topographic data of thrombi formed by circulating bovine blood through a BFS model for times ranging between 10 and 90 min at a constant upstream Reynolds number of 490. Thrombus height, length, exposed surface area, and volume are measured, and asymptotic behavior is observed for each as the blood circulation time is increased. Velocity patterns near, and wall shear stress (WSS) distributions on, the exposed thrombus surfaces are calculated using computational fluid dynamics (CFD). Both the mean and maximum WSS on the exposed thrombus surfaces are much more dependent on thrombus topography than thrombus size, and the best predictors for asymptotic thrombus length and volume are the reattachment length and volume of reversed flow, respectively, from the region of separated flow downstream of the BFS.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference62 articles.

1. Heart Disease and Stroke Statistics 2009 Update. A Report From the American Heart Association Statistics Committee and Stroke Statistics Subcommittee;Circulation,2009

2. Low Thromboembolism and Pump Thrombosis With the HeartMate II Left Ventricular Assist Device: Analysis of Outpatient Anti-Coagulation;J. Heart Lung Transpl.,2009

3. Stent Thrombosis in Randomized Clinical Trials of Drug-Eluting Stents;New Engl. J. Med.,2007

4. Prosthetic Heart Valve Thrombosis: Pathogenesis, Diagnosis and Management;Int. J. Cardiol.,2006

5. Experimental Fluid Mechanics of Pulsatile Artificial Blood Pumps;Annu. Rev. Fluid Mech.,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3