Mechanical and Tribological Studies of SU-8 Composites Filled With UHMWPE and Gum Acacia Under Dry and Bovine Serum Albumin Lubricated Conditions

Author:

Hirwani Jaswant K.1,Sinha Sujeet K.1

Affiliation:

1. Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas 110016, New Delhi, India

Abstract

Abstract SU-8 polymer was mixed with ultrahigh-molecular weight polyethylene (UHMWPE) particles in various weight percentages (wt%) to make composites. Uniform distribution of filler material was confirmed by optical microscopy imaging. Cross-sectional scanning electron microscopy (SEM) analysis showed the formation of fibrillar structure of UHMWPE which helped bind UHMWPE particles with SU-8 matrix. Gum acacia made a coating on the UHMWPE particles and helped in binding with the matrix. The compressive Young’s modulus and strength of the composites were found to decrease with UHMWPE filler addition. The composites were tested in ball-on-disk tribometer using 12 mm diameter stainless steel (grade 304) ball under a normal load of 20 N and sliding speed of 32 mm/s. SU-8 with 25 wt% of UHMWPE showed coefficient of friction of 0.1 and specific wear-rate of 6.27 × 10−5 mm3/Nm which were 52% and 61%, respectively, lower in comparison with those of bulk UHMWPE tested in aqueous solution of bovine serum albumin (BSA). Adding 10 wt% of gum acacia to the SU-8/UHMWPE composite had beneficial effects on the wear-rate as the specific wear-rate of this hybrid composite further dropped to 4.6 × 10−5 mm3/Nm which was 71% lower than that of bulk UHMWPE.

Publisher

ASME International

Subject

Surfaces, Coatings and Films,Surfaces and Interfaces,Mechanical Engineering,Mechanics of Materials

Reference39 articles.

1. Biological Reactions to Wear Debris in Total Joint Replacement;Ingham;Proc. Inst. Mech. Eng. Part H: J. Eng. Med.,2000

2. A Literature Review of the Association Between Wear Rate and Osteolysis in Total Hip Arthroplasty;Dumbleton;J. Arthroplasty,2002

3. Vitamin E Diffused, Highly Crosslinked UHMWPE: A Review;Oral;Int. Orthop.,2011

4. Comparison of the Wear, Wear Debris and Functional Biological Activity of Non-Crosslinked and Crosslinked GUR1020 and GUR 1050 Polyethylenes Used in Total Hip Prostheses;Tipper,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3