Biological reactions to wear debris in total joint replacement

Author:

Ingham E1,Fisher J2

Affiliation:

1. The University of Leeds Department of Microbiology UK

2. The University of Leeds Department of Mechanical Engineering UK

Abstract

The vast majority of total hip prostheses currently implanted consist of a hard metal or ceramic femoral head articulating against an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup. Over the last 10 years, evidence has accumulated to show that these prostheses are prone to failure due to late aseptic loosening and few survive beyond 25 years. With an increasing need to implant hip prostheses in the younger, more active patient the need to understand the mechanisms of failure and to develop artificial hip joints using alternative materials have become major issues in the orthopaedic community. This review focuses initially on our current understanding of the biological reactions to UHMWPE prosthetic wear debris in vivo and in vitro since this is believed to be the main cause of late aseptic loosening. While the precise mechanisms of osteolysis induced by UHMWPE wear debris have not been elucidated, the major message to emerge is that it is not the wear volume that determines the biological response to the debris, but the concentration of the wear volume that is within the critical size range (0.2-0.8 μm) for macrophage activation. The review then considers whether the problem of wear-debris-induced osteolysis may be overcome with the use of new generation metal-on-metal or ceramic-on-ceramic prostheses. For metal-on-metal prostheses, the prospects for increasing the osteolysis free life of the implant are good but additional biological problems associated with the nanometre size and reactivity of the wear particles in vivo may emerge. For the ceramic-on-ceramic prostheses, although initial prospects are encouraging, more data are needed on the characteristics of the wear particles generated in vivo before predictions can be made. It is concluded that the pre-clinical testing of any new materials for joint replacement must include an analysis of the wear particle characteristics and their biological reactivity in addition to the usual assessment of wear.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3