Effect of Air Extraction for Cooling and/or Gasification on Combustor Flow Uniformity
Author:
Wang T.1, Kapat J. S.1, Ryan W. R.2, Diakunchak I. S.2, Bannister R. L.2
Affiliation:
1. Gas Turbine Research Laboratory, Department of Mechanical Engineering, Fluor Daniel Building 239, Clemson University, Clemson, SC 29634-0921 2. Power Generation Business Unit, Siemens Westinghouse Power Corporation, Orlando, FL
Abstract
Reducing emissions is an important issue facing gas turbine manufacturers. Almost all of the previous and current research and development for reducing emissions has focused, however, on flow, heat transfer, and combustion behavior in the combustors or on the uniformity of fuel injection without placing strong emphasis on the flow uniformity of fuel injection without placing strong emphasis entering the combustors. In response to the incomplete understanding of the combustor’s inlet air flow field, experiments were conducted in a 48 percent scale, 360 deg model of the diffuser-combustor section of an industrial gas turbine. In addition, the effect of air extraction for cooling or gasification on the flow distributions at the combustors’ inlets was also investigated. The following three different air extraction rates were studied: 0 percent (baseline), 5 percent (airfoil cooling), and 20 percent (for coal gasification). The flow uniformity was investigated for the following two aspects: (a) global uniformity, which compared the mass flow rates of combustors at different locations relative to the extraction port, and (b) local uniformity, which examined the circumferential flow distribution into each combustor. The results indicate that even for the baseline case with no air extraction there was an inherent local flow non uniformity of 10 ∼ 20 percent at the inlet of each combustor due to the complex flow field in the dump diffuser and the blockage effect of the cross-flame tube. More flow was seen in the portion further away from the gas turbine center axis. The effect of 5 percent air extraction was small. Twenty percent air extraction introduced approximately 35 percent global flow asymmetry diametrically across the dump diffuser. The effect of air extraction on the combustor’s local flow uniformity varied with the distances between the extraction port and each individual combustor. Longer top hats were installed with the initial intention of increasing flow mixing prior to entering the combustor. However, the results indicated that longer top hats do not improve the flow uniformity; sometimes, adverse effects can be seen. Although a specific geometry was selected for this study, the results provide sufficient generality to benefit other industrial gas turbines.
Publisher
ASME International
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Reference8 articles.
1. Kapat, J. S., Agrawal, A. K., and Yang, T. T., 1994, “Air Extraction in a Gas Turbine for Integrated Gasification Combined Cycle (IGCC): Experiments and Analysis,” ASME Paper 94-GT-193. 2. Kapat, J. S., Wang, T., Ryan, W. R., Diakunchak, I. S., and Bannister, R. L., 1996, “Cold Flow Experiments in a Sub-Scale Model of the Diffuser Combustor Section of an Industrial Gas Turbine,” ASME Paper 96-GT-518. 3. Kapat
J. S.
, WangT., RyanW. R., DiakunchakI. S., and BannisterR. L., 1997, “Experimental Studies of Air Extraction for Cooling and/or Gasification in Gas Turbine Applications,” ASME JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER., Vol. 119, pp. 807–814. 4. Lefebvre, A. H., 1983, Gas Turbine Combustion, Hemisphere Pub. Corp., Washington, DC. 5. Lyons, V., 1981, “Effect of Fuel-Air-Ratio Non Uniformity on Emissions of Nitrogen Oxides,” NASA TP 1798.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|