Natural Cooling and Startup of Steam Turbines: Validity of the Over-Conductivity Function

Author:

Marinescu Gabriel1,Stein Peter1,Sell Michael1

Affiliation:

1. Alstom Power, Baden 5401, Switzerland e-mail:

Abstract

The temperature drop during natural cooling and the way in which the steam turbine restarts have a major impact on the cyclic lifetime of critical parts and on the cyclic life of the whole machine. In order to ensure the fastest startup without reducing the lifetime of the turbine critical parts, the natural cooling must be captured accurately in calculation and the startup procedure optimized. During the cool down and restart, all turbine components interact both thermally and mechanically. For this reason, the thermal analyst has to include, in his numerical model, all turbine significant parts—rotor, casings together with their internal fluid cavities, valves, and pipes. This condition connected with the real phenomenon lead-time—more than 100 hours for natural cooling—makes the analysis time-consuming and not applicable for routine projects. During the past years, a concept called “over-conductivity” was introduced by Marinescu et al. (2013, “Experimental Investigation Into Thermal Behavior of Steam Turbine Components—Temperature Measurements With Optical Probes and Natural Cooling Analysis,” ASME J. Eng. Gas Turbines Power, 136(2), p. 021602) and Marinescu and Ehrsam (2012, “Experimental Investigation on Thermal Behavior of Steam Turbine Components: Part 2—Natural Cooling of Steam Turbines and the Impact on LCF Life,” ASME Paper No. GT2012-68759). According to this concept, the effect of the fluid convectivity and radiation is replaced by a scalar function K(T) called over-conductivity, which has the same heat transfer effect as the real convection and radiation. K(T) is calibrated against the measured temperature on a Alstom KA26-1 steam turbine (Ruffino and Mohr, 2012, “Experimental Investigation on Thermal Behavior of Steam Turbine Components: Part 1—Temperature Measurements With Optical Probes,” ASME Paper No. GT2012-68703). This concept allows a significant reduction of the calculation time, which makes the method applicable for routine transient analyses. The paper below shows the theoretical background of the over-conductivity concept and proves that when applied on other machines than KA26-1, the accuracy of the calculated temperatures remains within 15–18 °C versus measured data. A detailed analysis of the link between the over-conductivity and the energy equation is presented as well.

Publisher

ASME International

Subject

Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3