Affiliation:
1. College of Mechanical Engineering, Chongqing University, Chongqing 400044, China
2. Indian Institute of Technology, Bhubaneswar 752050, India
Abstract
Abstract
Temperature is a significant factor affecting performance and safety of energy storage systems such as battery packs. How to design a reliable battery thermal management system (BTMS) is still a hot issue at present. Most of the past researches have focused on methods of reducing temperature rise. This paper mainly studies how to reduce the temperature deviation of the battery pack while ensuring heat dissipation conditions. This paper designs a mini-channel liquid cooling BTMS with a side cover to improve heat transfer capacity and thermal uniformity in battery packs. By analyzing different side cover materials, cooling water temperature, and water channel structure, the influence of different parameters on battery heat dissipation and uniformity is obtained. The main findings are: (1) the presence of the side cover can effectively reduce the maximum temperature and temperature deviation, and the material with high thermal conductivity is more likely to dissipate heat, (2) The increase of cooling water inlet temperature can improve temperature uniformity, and (3) When the cross-sectional area is fixed, as the channel depth increases, the temperature deviation gradually decreases.
Funder
China Postdoctoral Science Foundation
Subject
Mechanical Engineering,Mechanics of Materials,Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electronic, Optical and Magnetic Materials
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献