Finite Element and Experimental Cortex Strains of the Intact and Implanted Tibia

Author:

Completo A.1,Fonseca F.2,Simões J. A.1

Affiliation:

1. Departamento de Engenharia Mecânica, Universidade de Aveiro, 3810-193 Aveiro, Portugal

2. Faculdade de Ciências da Saúde, Universidade da Beira Interior, 6201-001 Covilhã, Portugal

Abstract

Finite Element (FE) models for the simulation of intact and implanted bone find their main purpose in accurately reproducing the associated mechanical behavior. FE models can be used for preclinical testing of joint replacement implants, where some biomechanical aspects are difficult, if not possible, to simulate and investigate in vitro. To predict mechanical failure or damage, the models should accurately predict stresses and strains. Commercially available synthetic femur models have been extensively used to validate finite element models, but despite the vast literature available on the characteristics of synthetic tibia, numerical and experimental validation of the intact and implant assemblies of tibia are very limited or lacking. In the current study, four FE models of synthetic tibia, intact and reconstructed, were compared against experimental bone strain data, and an overall agreement within 10% between experimental and FE strains was obtained. Finite element and experimental (strain gauge) models of intact and implanted synthetic tibia were validated based on the comparison of cortex bone strains. The study also includes the analysis carried out on standard tibial components with cemented and noncemented stems of the P.F.C Sigma Modular Knee System. The overall agreement within 10% previously established was achieved, indicating that FE models could be successfully validated. The obtained results include a statistical analysis where the root-mean-square-error values were always <10%. FE models can successfully reproduce bone strains under most relevant acting loads upon the condylar surface of the tibia. Moreover, FE models, once properly validated, can be used for preclinical testing of tibial knee replacement, including misalignment of the implants in the proximal tibia after surgery, simulation of long-term failure according to the damage accumulation failure scenario, and other related biomechanical aspects.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference38 articles.

1. Pre-Clinical Validation of a New Partially Cemented Femoral Prosthesis by Synergetic Use of Numerical and Experimental Methods;Viceconti;J. Biomech.

2. Modes of Failure of Cemented Stem-Type Femoral Components: A Radiographic Analysis of Loosening;Gruen;Clin. Orthop. Relat. Res.

3. NIH, 1982, NIH: Total Hip Joint Replacement, NIH Consens Statement 4, pp. 1–11.

4. The Effects of Cement-Stem Debonding in THA on the Long-Term Failure Probability of Cement;Verdonschot;J. Biomech.

5. Finite Element Models in Tissue Mechanics and Orthopaedic Implant Design;Prendergast;Clin. Biomech. (Los Angel. Calif.)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3