Stability of Three‐Dimensional Printed Custom‐Made Metaphyseal Cone for Tibial Bone Defects Reconstruction: A Finite Element Analysis and Biomechanical Study

Author:

Wang Xinguang12ORCID,Li Xinyu3,Wang Cheng12,Geng Xiao12,Chen Bo3,Dong Ziyang12ORCID,Li Yang12,Zhao Minwei12ORCID,Li Zijian12,Li Feng12,Wang Caimei3,Tian Hua12ORCID

Affiliation:

1. Department of Orthopaedics Peking University Third Hospital Beijing China

2. Engineering Research Center of Bone and Joint Precision Medicine Beijing China

3. Beijing 3D Printing Orthopedic Application Engineering Technology Research Center Beijing China

Abstract

ObjectivesThe reconstruction of bone defects in tibial revision knee arthroplasty is challenging. In this study, we evaluated the primary stability of a novel three‐dimensional (3D)‐printed custom‐made metaphyseal cone for Anderson Orthopedic Research Institute (AORI) IIb or III bone defect reconstruction in tibial revision knee arthroplasty using the combination of finite‐element analysis and biomechanical experiments.MethodsIn the finite‐element analysis, AORI II b and III medial tibial bone defects were designed at varying depths. A novel 3D‐printed custom‐made metaphyseal cone was designed and used to reconstruct the bone defect with or without a stem in simulated revision total knee arthroplasty (RTKA). A no‐stem group and a stem group were established (based on whether a stem was used or not). Von Mises stress and micromotion were calculated with varying depths of bone defects, ranging from 5 mm to 35 mm, and then micromotions at the bone–implant interface were calculated and compared with the critical value of 150 μm. In the biomechanical experiment, the no‐stem group was used, and the same bone defects were made in four synthetic tibias using patient‐specific instruments. Micromotions at the bone–implant interface were investigated using a non‐contact optical digital image correlation system and compared with the critical value of 150 μm.ResultsWhen the bone defect was <30 mm, micromotions at the bone–implant interface in the finite‐element analysis were all below 150 μm both in the stem groups and no‐stem groups, whereas those in the biomechanical experiment were also below 150 μm in the no‐stem group.ConclusionsThe 3D‐printed custom‐made metaphyseal cone in RTKA has excellent primary stability and does not require stems in reconstructing tibial AORI type IIb or III bone defects with a depth of <30 mm.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3