Experimentally Validated Computational Fluid Dynamics Model for Data Center With Active Tiles

Author:

Athavale Jayati,Joshi Yogendra1,Yoda Minami1

Affiliation:

1. George W. Woodruff School ofMechanical Engineering,Georgia Institute of Technology,Atlanta, GA 30332

Abstract

Abstract This paper presents an experimentally validated room-level computational fluid dynamics (CFD) model for raised-floor data center configurations employing active tiles. Active tiles are perforated floor tiles with integrated fans, which increase the local volume flow rate by redistributing the cold air supplied by the computer room air conditioning (CRAC) unit to the under-floor plenum. The numerical model of the data center room consists of one cold aisle with 12 racks arranged on both sides and three CRAC units sited around the periphery of the room. The commercial CFD software package futurefacilities6sigmadcx is used to develop the model for three configurations: (a) an aisle populated with ten (i.e., all) passive tiles; (b) a single active tile and nine passive tiles in the cold aisle; and (c) an aisle populated with all active tiles. The predictions from the CFD model are found to be in good agreement with the experimental data, with an average discrepancy between the measured and computed values for total flow rate and rack inlet temperature less than 4% and 1.7 °C, respectively. The validated models were then used to simulate steady-state and transient scenarios following cooling failure. This physics-based and experimentally validated room-level model can be used for temperature and flow distributions prediction and identifying optimal number and locations of active tiles for hot spot mitigation in data centers.

Publisher

ASME International

Subject

Electrical and Electronic Engineering,Computer Science Applications,Mechanics of Materials,Electronic, Optical and Magnetic Materials

Reference20 articles.

1. Smart Cooling of Data Centers,2003

2. Bash, C. E., Patel, C. D., and Sharma, R. K., 2006, “Dynamic Thermal Management of Air Cooled Data Centers,” Tenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronics Systems (ITHERM), San Diego, CA, May 30–June 2, pp. 445–452.10.1109/ITHERM.2006.1645377

3. Cooling Analysis of Data Centers: CFD Modeling and Real-Time Calculators,2008

4. Viability of Dynamic Cooling Control in a Data Center Environment;ASME J. Electron. Packag.,2006

5. Local Cooling Control of Data Centers With Adaptive Vent Tiles,2009

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3