Cooling Technologies for Internet Data Center in China: Principle, Energy Efficiency, and Applications

Author:

Huang Xiaofei12,Yan Junwei12ORCID,Zhou Xuan12,Wu Yixin12,Hu Shichen1

Affiliation:

1. School of Mechanical & Automotive Engineering, South China University of Technology, No. 381, Wushan Rd., Tianhe District, Guangzhou 510640, China

2. Guangdong Artificial Intelligence and Digital Economy Laboratory, No. 70, Yuean Rd., Haizhu District, Guangzhou 510640, China

Abstract

The highlighted energy consumption of Internet data center (IDC) in China has become a pressing issue with the implementation of the Chinese dual carbon strategic goal. This paper provides a comprehensive review of cooling technologies for IDC, including air cooling, free cooling, liquid cooling, thermal energy storage cooling and building envelope. Firstly, the environmental requirements for the computer room and the main energy consumption items for IDC are analyzed. The evaluation indicators and government policies for promoting green IDC are also summarized. Next, the traditional cooling technology is compared to four new cooling technologies to find effective methods to maximize energy efficiency in IDC. The results show that traditional cooling consumes a significant amount of energy and has low energy efficiency. The application of free cooling can greatly improve the energy efficiency of IDC, but its actual implementation is highly dependent on geographical and climatic conditions. Liquid cooling, on the other hand, has higher energy efficiency and lower PUE compared to other cooling technologies, especially for high heat density servers. However, it is not yet mature and its engineering application is not widespread. In addition, thermal energy storage (TES) based cooling offers higher energy efficiency but must be coupled with other cooling technologies. Energy savings can also be achieved through building envelope improvements. Considering the investment and recovery period for IDC, it is essential to seek efficient cooling solutions that are suitable for IDC and take into account factors such as IDC scale, climate conditions, maintenance requirements, etc. This paper serves as a reference for the construction and development of green IDC in China.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Reference145 articles.

1. Cooling technologies for data centres and telecommunication base stations—A comprehensive review;Zhang;J. Clean. Prod.,2022

2. A review of thermal management and innovative cooling strategies for data center;Nadjahi;Sustain. Comput. Inform. Syst.,2018

3. A review on airflow management in data centers;Chu;Appl. Energy,2019

4. Data Center Energy Supply under the Energy Internet;Yonyzhen;Electronic,2020

5. North China Electric Power University (2019). Report for energy consumption and renewable energy potential of data center in China. Wind Energy, 10, 8.

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3