Feedback Stability Limits for Active Isolation Systems with Reactive and Inertial Actuators

Author:

Elliott S. J.1,Serrand M.1,Gardonio P.1

Affiliation:

1. Institute of Sound and Vibration Research, University of Southampton, Southampton SO17 1BJ, England

Abstract

Some of the compromises inherent in using a passive system to isolate delicate equipment from base vibration can be avoided using fully active skyhook damping. Ideally, a secondary force, which is made proportional to the absolute equipment velocity by a feedback controller, acts only on the equipment and so the response of the system under control, between the secondary force input and the collocated velocity output, i.e., the plant response, is proportional to the driving point mobility of the mounted equipment. The frequency response of the plant is guaranteed to have a positive real part under these ideal conditions, and so the feedback system is unconditionally stable for any positive real feedback gain. In practice, the actuator generating the secondary force must either react off the base structure or an inertial mass. In both of these cases the plant response is no longer guaranteed to be positive real and so the control system may become unstable at high gains. Expressions for the overall plant responses are derived for both of these arrangements, in terms of the dynamic response of the individual parts of the isolation system. When using a soft mount, the stability of the reactive system is found to be surprisingly tolerant of the additional contributions to the plant response from the reactive force. In order for the inertial system to be stable with a high feedback gain, however, the natural frequency of the actuator must be well below the natural frequency of the equipment on the mounts. Experimentally measured plant responses are compared with those predicted from theory for both types of actuator and the performance of practically implemented feedback controllers is discussed.

Publisher

ASME International

Subject

General Engineering

Reference11 articles.

1. Crede, C. E., and Ruzicka, J. E., 1996, “Theory of Vibration Isolation,” Chapter 30, C. M. Harris, ed., Shock and Vibration Handbook, McGraw Hill, New York.

2. Ungar, E. E., 1992, “Vibration Isolation,” Chapter 11, Noise and Vibration Control Engineering, L. Beranek and I. L. Ver, eds., Wiley, Chichester.

3. Karnopp, D. , 1995, “Active and Semi-active Vibration Isolation,” ASME J. Mech. Des., 117, pp. 177–185.

4. Fuller, C. R., Elliott, S. J., and Nelson, P. A., 1996, Active Control of Vibration, Academic Press.

5. Beard, A. M., von Flotow, A. H., and Schubert, D. W., 1994, “A Practical Product Implementation of an Active/Passive Vibration Isolation System,” Proc. IUTAM Symposium on the Active Control of Vibration, Bath, pp. 101–108.