Affiliation:
1. Center of Materials Research, Department of Biomedical Engineering, University of Iowa, Iowa City, IA 52242
Abstract
Based on an idealized model of a homogeneous, isotropic beam-column, the second stiffest axis under static loading was derived. The maximum allowable force for the second stiffest axis was then examined. The ratio of the maximum allowable forces of the second stiffest axis to the stiffest axis was established. The stiffness ratio of the second stiffest axis to the stiffest axis was also found. Taking buckling into consideration, the safe load region for all possible acting directions was derived. The implications of the idealized model for cervical spine trauma are discussed.
Subject
Physiology (medical),Biomedical Engineering
Cited by
30 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献