Physiological Flow Simulation in Residual Human Stenoses After Coronary Angioplasty

Author:

Banerjee Rupak K.1,Back Lloyd H.2,Back Martin R.3,Cho Young I.4

Affiliation:

1. Bioengineering and Physical Science Program, Bldg. 13, Rm. 3N17, National Institute of Health (NIH), Bethesda, MD 20892

2. Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109

3. Division of Vascular Surgery, University of South Florida, College of Medicine, Tampa, FL 33606

4. Mechanical Engineering and Mechanics Department, Drexel University, Philadelphia, PA 19104

Abstract

To evaluate the local hemodynamic implications of coronary artery balloon angioplasty, computational fluid dynamics (CFD) was applied in a group of patients previously reported by [Wilson et al. (1988), 77, pp. 873–885] with representative stenosis geometry post-angioplasty and with measured values of coronary flow reserve returning to a normal range (3.6±0.3). During undisturbed flow in the absence of diagnostic catheter sensors within the lesions, the computed mean pressure drop Δp˜ was only about 1 mmHg at basal flow, and increased moderately to about 8 mmHg for hyperemic flow. Corresponding elevated levels of mean wall shear stress in the midthroat region of the residual stenoses, which are common after angioplasty procedures, increased from about 60 to 290 dynes/cm2 during hyperemia. The computations (Re˜e≃100-400;αe=2.25) indicated that the pulsatile flow field was principally quasi-steady during the cardiac cycle, but there was phase lag in the pressure drop−mean velocity Δp−u¯ relation. Time-averaged pressure drop values, Δp˜, were about 20 percent higher than calculated pressure drop values, Δps, for steady flow, similar to previous in vitro measurements by Cho et al. (1983). In the throat region, viscous effects were confined to the near-wall region, and entrance effects were evident during the cardiac cycle. Proximal to the lesion, velocity profiles deviated from parabolic shape at lower velocities during the cardiac cycle. The flow field was very complex in the oscillatory separated flow reattachment region in the distal vessel where pressure recovery occurred. These results may also serve as a useful reference against catheter-measured pressure drops and velocity ratios (hemodynamic endpoints) and arteriographic (anatomic) endpoints post-angioplasty. Some comparisons to previous studies of flow through stenoses models are also shown for perspective purposes. [S0148-0731(00)00304-6]

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 35 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3