Physiological Flow Simulation in Residual Human Stenoses After Coronary Angioplasty
Author:
Banerjee Rupak K.1, Back Lloyd H.2, Back Martin R.3, Cho Young I.4
Affiliation:
1. Bioengineering and Physical Science Program, Bldg. 13, Rm. 3N17, National Institute of Health (NIH), Bethesda, MD 20892 2. Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 3. Division of Vascular Surgery, University of South Florida, College of Medicine, Tampa, FL 33606 4. Mechanical Engineering and Mechanics Department, Drexel University, Philadelphia, PA 19104
Abstract
To evaluate the local hemodynamic implications of coronary artery balloon angioplasty, computational fluid dynamics (CFD) was applied in a group of patients previously reported by [Wilson et al. (1988), 77, pp. 873–885] with representative stenosis geometry post-angioplasty and with measured values of coronary flow reserve returning to a normal range (3.6±0.3). During undisturbed flow in the absence of diagnostic catheter sensors within the lesions, the computed mean pressure drop Δp˜ was only about 1 mmHg at basal flow, and increased moderately to about 8 mmHg for hyperemic flow. Corresponding elevated levels of mean wall shear stress in the midthroat region of the residual stenoses, which are common after angioplasty procedures, increased from about 60 to 290 dynes/cm2 during hyperemia. The computations (Re˜e≃100-400;αe=2.25) indicated that the pulsatile flow field was principally quasi-steady during the cardiac cycle, but there was phase lag in the pressure drop−mean velocity Δp−u¯ relation. Time-averaged pressure drop values, Δp˜, were about 20 percent higher than calculated pressure drop values, Δps, for steady flow, similar to previous in vitro measurements by Cho et al. (1983). In the throat region, viscous effects were confined to the near-wall region, and entrance effects were evident during the cardiac cycle. Proximal to the lesion, velocity profiles deviated from parabolic shape at lower velocities during the cardiac cycle. The flow field was very complex in the oscillatory separated flow reattachment region in the distal vessel where pressure recovery occurred. These results may also serve as a useful reference against catheter-measured pressure drops and velocity ratios (hemodynamic endpoints) and arteriographic (anatomic) endpoints post-angioplasty. Some comparisons to previous studies of flow through stenoses models are also shown for perspective purposes. [S0148-0731(00)00304-6]
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference35 articles.
1. Cole, J. S., and Hartley, C. J., 1977, “The Pulsed Doppler Coronary Artery Catheter: Preliminary Report of a Technique for Measuring Rapid Changes in Coronary Flow Velocity in Man,” Circulation, 56, pp. 18–25. 2. Wilson, R. F., Johnson, M. R., Marcus, M. L., Alyward, P. E. G., Skorton, D. J., Collins, S., and White, C. W., 1988, “The Effect of Coronary Angioplasty on Coronary Flow Reserve,” Circulation, 77, pp. 873–885. 3. Doucette, J. W., Corl, P. D., Payne, H. M., Flynn, A. E., Goto, M. N., Nassi, M., and Segal, J., 1992, “Validation of a Doppler Guide Wire for Intravascular Measurement of Coronary Artery Flow Velocity,” Circulation, 85, pp. 1899–1911. 4. Segal, J., Kern, M. J., Scott, N. A., King, S. B., III, Doucette, J. W., Heuser, R. R., Ofili, E., and Siegel, R., 1992, “Alterations of Phasic Coronary Artery Flow Velocity in Humans During Percutaneous Coronary Angioplasty,” J. Am. Coll. Cardiol., 20, pp. 276–286. 5. Anderson, H. V., Roubin, G. S., Leimgruber, P. P., Cox, W. R., Douglas, J. S., Jr., King, S. B., and Gruentzig, A. R., 1986, “Measurement of Transstenotic Pressure Gradient During Percutaneous Transluminal Coronary Angioplasty,” Circulation, 73, pp. 1223–1230.
Cited by
35 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|