The effect of coronary angioplasty on coronary flow reserve.

Author:

Wilson R F1,Johnson M R1,Marcus M L1,Aylward P E1,Skorton D J1,Collins S1,White C W1

Affiliation:

1. Department of Internal Medicine, University of Iowa, Iowa City.

Abstract

To determine the effects of coronary angioplasty on coronary flow reserve (CFR), we studied 32 patients before and immediately after single-vessel coronary angioplasty and 31 patients evaluated late after angioplasty (7.5 +/- 1.2 months, mean +/- SEM). The geometry (percent area stenosis and minimal cross-sectional area) of each lesion was determined by quantitative coronary angiography (Brown/Dodge method) and the integrated optical density was measured by videodensitometry. CFR was measured with a No. 3F coronary Doppler catheter placed immediately proximal to the lesion and a maximally vasodilating dose of intracoronary papaverine. The translesional pressure gradient was obtained in all lesions before and immediately after angioplasty and in 18 of 31 vessels late after angioplasty. CFR immediately after angioplasty returned to normal levels (greater than 3.5 peak/resting velocity ratio) in 14 of 31 patients and was improved, although not normalized, in the remaining 17 patients. CFR immediately after dilation was not significantly correlated with any of the angiographic variables of arterial stenosis nor the resting pressure gradient. Moreover, the pressure gradient and absolute distal coronary pressure at peak hyperemia were not significantly different in vessels with normal and those with abnormal flow reserve immediately after dilation, suggesting that the residual stenosis did not significantly limit hyperemia. Late after angioplasty, however, a significant relationship emerged between CFR and all four indexes of residual arterial stenosis (percent area stenosis r = .70, p less than .01; minimum arterial cross-sectional area r = .70, p less than .01; integrated optical density r = .60, p less than .01; and translesional pressure gradient r = .77, p less than .01). Furthermore, in the absence of restenosis, CFR eventually normalized in all patients. These findings demonstrate that in one-half of patients there is a transient reduction in coronary flow reserve immediately after angioplasty. In the absence of restenosis, coronary flow reserve later normalizes. Consequently, measurements of coronary flow reserve immediately after angioplasty may not reflect the eventual success of the procedure in removing physiologic obstruction to coronary blood flow.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 330 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3